Page 2: ...able from the manufacturer or his service agent Shields lenses or ultraviolet screens shall be changed if they have become visibly damaged to such an extent that their effectiveness is impaired for ex...

Page 3: ...als and or li quids The fixture must be fixed at least 20cm from surrounding walls To avoid condensation to be formed inside allow this unit to adapt to the surrounding temperatu res when bringing it...

Page 4: ...or animals and never leave this device running unattended The legal requirements for using laser entertainment products vary from country to country The user is responsible for the legal requirements...

Page 5: ...any flammable materials and or liquids The fixture must be fixed at least 20cm from surrounding walls The device should be installed out of reach of people and outside areas where persons may walk by...

Page 6: ...DMX output input inter face The connection between socket and cable as below note the plug socket s 3 pin number and position Note XLR plug socket s 3pin can not be touched by inner hull connection be...

Page 7: ...ommu nication 9 Interlock Switch For connecting interlock button and emergen cy closing light 10 Key Switch Laser ON OFF only for professional staff 11 DMX Indica tor In DMX model red indicate light o...

Page 8: ...h help of LCD con trol panel is very easy to set and change the operating mode of laser After every resetting and saved the new mode information will be shown on LCD monitor at next power Model choice...

Page 9: ...saving mode Digital tube will display a point if there s no operation in 30s press any button or IR remote control to activate it TEST Testing mode 1 functional testing mode auto sound program testin...

Page 10: ...show ENTER into the next step To choose the ef fect speed through the UP DO WN button S 1 S 99 Ef fect speed ad justment 1 is the slowest 99 is the fastest ENTER confirm and back to the pre vious step...

Page 11: ...ck to the pre vious step DMX Mode 02 11CH Selec ting the channel d001 dXXX Setting the ad dress Sy stem Set ting LED display power saving mode ENTER into the next step ON turn on the nixie tube power...

Page 12: ...ONAL DESCRIPTION CH01 000 009 Blackout 010 026 AUT0 027 043 AUT1 044 060 AUT2 061 077 AUT3 078 094 AUT4 095 111 AUT5 112 127 AUT6 128 145 SOU0 146 163 SOU1 164 181 SOU2 182 199 SOU3 200 217 SOU4 218 2...

Page 13: ...nd strobe CH03 000 004 STOP 005 127 Rotate Clockwise slow to fast 128 133 STOP 134 255 Rotate Anticlockwise slow to fast LED 2 CH04 000 024 Blackout 025 049 Blue 050 074 Amber 075 099 White 100 124 BA...

Page 14: ...low to fast max 30HZ 255 255 Sound strobe mode CH09 000 004 STOP 005 127 Rotate Clockwise slow to fast 128 133 STOP 134 255 Rotate Anticlockwise slow to fast STROBE CH10 000 009 Blackout 010 019 Progr...

Page 15: ...am15 slow to fast 160 169 Program16 slow to fast 170 179 Program17 slow to fast 180 189 Program18 slow to fast 190 199 Program19 slow to fast 200 255 Always ON CH11 valid in CH10 bet ween 200 255 000...

Page 16: ...program and color change will be paused press again to continue play Color Chan ging Color choice of LED or Laser Press again LED restore to the default color press again Laser restore to the default...

Page 17: ...6kg Power 40W Voltage 100 240V 50 60Hz Strobe LED 0 5W 12 Red LED 3W 1 Green LED 3W 1 Blue LED 3W 1 White LED 3W 1 Amber LED 3W 1 Red Laser 100mW 650nm Green Laser 30mW 532nm DMX Channels 2 11 Auto S...

Page 18: ...pianto di alimentazione dotato di una messa a terra se condo norma EN 60598 1 Si raccomanda inoltre di proteggere le linee di alimentazione delle unit dai contatti indiretti e o cortocircuiti verso ma...

Page 19: ...cortocircuiti verso massa tramite l uso di interruttori differenziali opportunamente dimensionati 1 6 Pulizia E possibile eliminare la polvere utilizzando un getto d aria compressa o un panno inumidi...

Page 20: ...del TSL o Resposabile TSL Predispone affinch il tragitto del fascio non sia per quanto possibile all altezza degli occhi degli spettatori Evita riflessioni speculari non volute e valuta e previene il...

Page 21: ...ano correttamente predisposte prima di in viare il fascio in un area che non sotto la propria diretta visione Astenersi dal rimuovere o modificare senza autorizzazione del Responsabile i dispositivi d...

Page 22: ...rotezione garantita dalle reazioni di difesa naturale compreso il riflesso palpebrale Classe 2M Laser che emettono radiazione con 400 nm l 700 nm per cui la protezione garantita dalle reazioni di dife...

Page 23: ...targhette indicatrici e di avvertimento L apparecchio deve essere corredato dalle seguenti targhette Targhetta generica di segnalazione radiazioni laser Targhetta di segnalazione classificazione lase...

Page 24: ...Targhetta di segnalazione potenza laser Obbligatorie 5 Montaggio in sicurezza Immagini IMPORTANTE Atomic4Dj TWIN200 Led Laser www Atomic4Dj com 24...

Page 25: ...qualificato Non esporre questo apparecchio alla pioggia o all umidit Conservare le istruzioni Il presente manuale parte integrante del prodotto e lo deve accompagnare in caso di eventuali cambi di pr...

Page 26: ...dell alimentazione Non ostruire le griglie di ventilazione dell apparato Evitare che l unit lavori in sovraccarico per tempo prolungato Per ragioni di sicurezza non annullare il collegamento a massa d...

Page 27: ...la data di garanzia difetti imputabili a materiali difettosi o difetti di costruzione occorre comunicare tempestivamente il problema al proprio rivenditore o distributore allegando fattura commerciale...

Page 28: ...ntioned above is in conformity with norm setting regulations Directive EP and C No 2004 108 EC EN 55015 2006 A1 2007 A2 2009 EN 61547 2009 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 Directive...

Reviews: