MAINTENANCE SCHEDULE

Regular maintenance is most important for the maximum 
performance and safe operation of the generator.

ITEM

TASK

DAILY

1ST MONTH 

OR  

10 HOURS

EVERY 3 

MONTHS OR 

50 HOURS

EVERY 6 

MONTHS OR 

100 HOURS

EVERY 12 

MONTHS OR 

300 HOURS

General Inspection

Spark Plug

Check condition, 
adjust gap, clean

 

REPLACE

Engine Oil*

Check oil level

Replace

*

Air Filter

Clean, replace 
if necessary

Fuel Filter

Clean, replace 
if necessary

Choke

Check operation

Valve 
clearance

Check and adjust 
when engine is cold

Fuel Line

Check hose for 
damage, replace 
if necessary

Exhaust 
System

Check for leakage, 
retighten or replace 
gasket if necessary

Check spark arrestor, 
clean or replace 
if necessary

Cooling 
System

Check fan for damage

Starting 
System

Check recoil starter 
operation cord 
and handle

Idle Speed

Check and adjust 
engine idle speed

Fittings/
Fasteners

Check and tighten 
if necessary

Crankcase 
Breather

Check hose for 
cracks or damage, 
replace if necessary

*  

Note: it is recommended to replace the engine oil and clean oil filter after the first 10 hours of operation  
and then every 50 hours.

Summary of Contents for AI2800X

Page 1: ...USER MANUAL...

Page 2: ...emissions of poisonous carbon monoxide gas Be careful not to touch the exhaust system during operation because it can cause burns Pay attention to the warning labels because the engine exhaust system...

Page 3: ...s for 12 months 500 hours whatever period expires first commencing from the date of purchase and is for the original owner only and cannot be transferred For all warranty service and repairs contact F...

Page 4: ...ntrol Panel 4 Muffler 5 Side Maintenance Cover 6 Solid Wheels 7 Carrying Handle 8 Fuel Tap Knob 9 Choke 10 Economy Control Switch 11 Ground Terminal 12 12V DC Socket 13 Circuit Breaker Push Button 14...

Page 5: ...C circuit breaker turns off automatically when the load exceeds the generator rated output CAUTION Reduce the load to within specified generator rated output if the DC circuit breaker turns off FUEL T...

Page 6: ...l level by removing the fuel tank cap to visually inspect Add fuel if level is too low Do not refuel while generator is running Tighten the cap securely after filling Petrol is highly flammable and ex...

Page 7: ...ine oil Fill with oil or it will not start Do not tilt the generator when adding engine oil This could result in overfilling and damage to the engine In regular use make sure the engine oil is at the...

Page 8: ...after refilling pull the recoil handle approximately 6 times This will pump fuel up to the carburettor 6 Pull the recoil starter handle slowly until resistance is felt Return the handle to its origin...

Page 9: ...c motor driven appliances may be up to three times the running watts 4 To convert voltage and amperage to watts Volts V x Amps A Watts W OVERLOAD INDICATOR LIGHT The overload indicator light RED comes...

Page 10: ...d making sure of the and polarity Check the DC circuit breaker is set to ON to start charging the battery CAUTION Turn off the economy control switch while charging the battery HOUR METER By pressing...

Page 11: ...k operation Valve clearance Check and adjust when engine is cold Fuel Line Check hose for damage replace if necessary Exhaust System Check for leakage retighten or replace gasket if necessary Check sp...

Page 12: ...crews CAUTION Ensure no foreign material enters the crankcase Do not tilt the generator when adding engine oil This could result in overfilling and damage to the engine AIR FILTER A dirty air cleaner...

Page 13: ...ve the spark arrestor mesh screen 3 Carefully remove the carbon deposits from the spark arrestor using a wire brush 4 Replace the spark arrestor if damaged 5 Re fit the spark arrestor and attach using...

Page 14: ...vent closed Turn fuel tank cap vent to ON Choke in the wrong position Pull CHOKE to START push in to RUN when started Low engine oil alert light ON Add engine oil to high level on dipstick Spark plug...

Page 15: ...cement 171cc Max Output Fuel Unleaded petrol Fuel tank capacity 6 0L Continuous run time 100 load 3 4hr 50 load 5 4hr Noise level full load 7m 67dB Lubricating oil SAE 10W30 or 15W40 Lubricating oil c...

Page 16: ...Distributed by Primus Australia Pty Ltd Bundoora VIC 3083 www atomicgenerators com au ATM028...

Reviews: