APPLICATION

The  Viper Night Vision Scope is a complex opticoelectronic system for individual use. The 

device consists of (see above figure) the objective lens assembly, eyepiece and the body. The 

body contains a 1st Gen.+ image intensifier tube assembly with an integrated high voltage 

power source and the three volt battery housing. When installing the battery one should keep 

in mind that the polarity of the battery should coincide with the diagram on the body next to the 

battery housing cap.
Objective lens protective cover (not shown) is intended to protect the objective lens from dust 

and scratches. It also will act as a daylight filter, allowing you to test the scope in daylight or 

other bright light situations. The pinhole in the center of the protective cover allows the user to 

check the operation ability of the device in daylight conditions.

NOTE: 

Do not test the scope in daylight conditions even with the daylight filter/lens cap on for 

more than ten (10) minutes.

The device is powered up by sliding the switch on the rear of the unit labeled “PWR”. You may 

notice a persistent green glow for up to five (5) minutes after you have turned the unit off. This 

is normal for the 1st Gen. light intensifier tube.

OPERATION

•  Take the monocular out of the case.
•  Install the battery into the housing with the polarity order as shown on the scope. Battery 

Type: 3 Volt Lithium, #CR123A .

•  Slide the switch to turn the unit on with the protective lens cover still attached to the lens. 

Do 

not turn the unit on in the daytime without the protective lens cap on.

 You should see 

green glow in the eyepiece.

•  Observe the scene and adjust the diopter for optimal image clarity.
•  You may now enter a dark environment or simply shut the lights off in order to darken the 

room.

•  Next, remove the lens cap/daylight filter. Adjust the front lens for the distance of the focus. 

You should not have to readjust the diopter.

FOCUSING

To focus the Viper, first you will need to adjust the diopter. Simply turn the 

diopter clockwise until it stops. Then, while looking throught the diopter at 

an object, slowly turn the diopter back counter clockwise until the grain in 

the image is sharp.

NOTE: 

We suggest that you focus the diopter during daylight with the 

filter on.
Next focus the front lens until the image and the grain are both sharp. When 

you are in low-light conditions and the daylight filter is off, you may focus the 

front lens to receive sharp image, the diopter should not be adjusted.

NOTE: 

The front lens should be readjusted as you view objects at different 

distances.

Summary of Contents for Viper

Page 1: ...AMERICAN TECHNOLOGIES NETWORK CORP u s e r s g u i d e Viper ...

Page 2: ...reat for hunting camping boating or surveillance Total darkness technology Automatic brightness control Built in IR illuminator Manual focus Adjustable eyepiece High res 1st Gen intensifier tube Rugged and versatile design Light weight and comfortable Water and dust resistant Single switch button operation Superb 1X lens system Optional Doubler Lens allows 4X to 8X magnification Soft case Two year...

Page 3: ...rmal for the 1st Gen light intensifier tube OPERATION Take the monocular out of the case Install the battery into the housing with the polarity order as shown on the scope Battery Type 3 Volt Lithium CR123A Slide the switch to turn the unit on with the protective lens cover still attached to the lens Do not turn the unit on in the daytime without the protective lens cap on You should see green glo...

Page 4: ...the 90mm lens to a Viper without a doubler NOTE When attaching the doubler do not be afraid to use a little force USING THE CAMERA ADAPTER optional To use your Viper with a 35mm camera or camcorder you will need the following 1 If you plan to use a camcorder then your camcorder must have a MACRO feature Most modern camcorders today have a MACRO feature built in 2 If you plan to use a 35mm camera y...

Page 5: ...t ing your VIPER on your head is to fit the head gear to your size Adjust the headgear fist befor attaching the VIPER to it 2 Loosen all the straps and plase the head gear on your head 3 You will want to tighten the side straps Figure H1 fist 4 Then secure the top strep Figure H2 This one is rather tight so you might need to remove it from your head when you are adjusting the strap 5 And last you ...

Page 6: ...eir surface with a Photographic lens cleaning tissue Keep lens cap daylight filter on when not in use The Viper is not harmful to the user or the environment Do not disassemble except to clean the front lens and eyepiece it will void your warranty Evaluate the scope function by looking through it in a lit environment with the daylight filter lens cap on Never use in daylight without the daylight f...

Page 7: ...ons suits proceedings costs expenses damages or liabilities arising out of the use of this product Operation and use of the product are the sole respon sibility of the Customer ATN s sole undertaking is limited to providing the products and services outlined herein in accordance with the terms and conditions of this Agreement The provision of products sold and services performed by ATN to the Cust...

Page 8: ...nden Ave Suite 1B South San Francisco CA 94080 phone 800 910 2862 650 875 0130 fax 650 875 0129 European Office phone 44 0 870 0111286 fax 44 0 845 3349142 The following countries can use our toll free number 00 800 9102 8620 Austria France Germany Holland Italy Spain Sweden Switzerland www atncorp com 2001 ATN Corporation ...

Reviews: