background image

7

WARNINGS AND CAuTIONS

• Do not forget to turn off the PS-22 when it is not in use. If you do not plan to use your unit for a period 

of more than 10 days, you should remove the batteries. 

• Keep lens cap on whe

n PS-22 is not in use

.

• Avoid contact with dust, steam, and gas.
• The PS-22  is not harmful for its user or environment.
• Do not disassemble:

 it will void your warranty.

• Never use in daylight conditions without the lens cap on. 
• 

Never point the PS-22 at a bright light source.

 If the device shuts off automatically after directing it 

at a bright light source, turn the unit off and wait for 1-2 minutes before turning the unit back on.

• Adverse atmospheric conditions such as fog, smog, or haze and a lack of ambient light (moon or 

starlight) may decrease the effective viewing distance. All technical data for this unit was compiled in 

a controlled environment.

• If you use the rubber eyecaps for a long period of time, you may suffer skin inflammation. If you de-

velop any symptoms, consult a doctor immediately.

TROuBLESHOOTING

Q: 

Flashes, flickers or clicking occur while operating

S:

 If it occurs within the first five minutes of inserting new batteries, it is normal and the device will 

resume normal operation soon thereafter. If it occurs for more than 10 minutes, contact for service 

instructions.

Q:

 Dark spots on screen.

S:

 These are either cosmetic blemishes in the intensifier tube or dust particles. 

Q:

 Screen becomes darker than at previous use.

S:

 Replace batteries. If problem persists, contact your dealer or other authorized service representa-

tive for service instructions.

Q:

 Image not clear.

S:

 Adjust objective lens, and/or the eyepiece. 

TuBE MAINTENANCE / REPLACEMENT 

Tube maintenance/replacement is to be performed by qualified technicians only. These proce-

dures attempted by non-qualified personnel will void warranty.

1) Loosen slightly (do not remove completely) three set screws (1) at the Objective Locking Ring side (2).
2) Unscrew the Objective Locking Ring (2) and the Objective Focusing Ring (3).
3) Unscrew the Objective Directive Screw (4).
5) Disassemble the Objective (5) from the Body (6).
6) Unscrew the IIT Locking Ring (7) from the Body.
7) Replace IIT (8) with another one. During this step pay attention to Locking-finger (9) that must  con-

sist with the groove in IIT body.
8) Do the steps 1-7 mentioned above in reverse order to assemble the PS-22. 

Summary of Contents for PS-22

Page 1: ...It is unlawful and strictly prohibited to export or attempt to export or otherwise transfer or sell any hardware or technical data or furnish any service to any foreign person whether abroad or in the...

Page 2: ...8 WEAVER MOUNT Adapter for A R M S mount OPTIONAL PICATINNY RAIL SCOPE MOUNTING SYSTEM OPTIONAL PLATFORM RING OPTIONAL REMOTE CONTROL REMOTE CONTROL CAP Day scope light suppressor OPTIONAL The informa...

Page 3: ...high level illumination The pinhole in cover allows the user to check the operation ability of the device in highlight conditions The device has a built in Automatic Brightness Control This system aut...

Page 4: ...e tightened again after continuous shooting Mounting onto the Weaver rail with A R M S Mount 1 Mount the A R M S Adapter optional A onto the body of PS 22 with two screws M4x7 B from the kit 2 Mount t...

Page 5: ...5 10x40 Leupold VX II 3 9x40 48 mm Zeiss 1 5 6x42 Swarovski PV N 2 5 10x42 from 48 7 to 49 0 mm Meopta Artemis 3000 3 9x42 49 5 mm Meopta Artemis 3000 4 12x40 50 mm Schmidt Bender 10x42 PMII 4 56 mm...

Page 6: ...from the Plat form Ring 2 Place the top and lower parts of the Platform Ring around your daytime scope tube B as shown on the picture 3 Tighten hard the two screws set A Daytime Scope Light Suppresso...

Page 7: ...ope is turned off immediately after releasing remote control button To switch the Remote Control mode OFF rotate the Operation Switch from the STB position IR Illuminator The IR illuminator greatly en...

Page 8: ...ating S If it occurs within the first five minutes of inserting new batteries it is normal and the device will resume normal operation soon thereafter If it occurs for more than 10 minutes contact for...

Page 9: ...s sold and services performed by ATN to the Customer shall not be interpreted construed or regarded either expressly or implied as being for the benefit of or creating any obligation toward any third...

Page 10: ...ry CR123A A1 5 AT 146531 706 Battery Cap A1 6 AT 146531 707 Image Intensifier Tube A1 7 AT 146531 708 IIT Locking Ring A1 8 AT 146531 709 Back Cap A1 9 AT 146532 700 Accessories 1 From the Kit A2 AT 1...

Page 11: ...48 mm diameter A3 7 AT 146534 757 Scope Mounting System Insert with 48 7 49 mm diameter A3 7 AT 146534 758 Scope Mounting System Insert with 49 5 mm diameter A3 7 AT 146534 759 Scope Mounting System...

Page 12: ...n Mateo Avenue South San Francisco CA 94080 phone 800 910 2862 650 989 5100 fax 650 875 0129 European Office phone 44 0 870 0111286 fax 44 0 845 3349142 The following countries can use our toll free n...

Reviews: