By pressing the “SL” button a third time you will then see a 

red diode

 “

I

” light up. The 

red diode

 represents the 100M 

infra-red illuminator’s brightness adjustment mode. Adjust-

ments should be easily seen if you look through the Aries 

258 while you work the “+” and “–” adjustment buttons.
Infra-red illuminators, or IR illuminators, are common to 

night vision. The IR light greatly enhances the perform-

ance of the Aries 258, while remaining almost totally invis-

ible to the naked eye. The IR illuminator on the Aries 258 

is the 100M and is located near the windage and elevation 

adjustments.
In a dark environment, power up the Aries scope. Now, find 

a scene and examine it without the IR on, and with the IR on. Note the difference in illumina-

tion. It is important to remember that the IR illuminator is simply an infra red light source, and 

like any light source, It may loose its effectiveness over a great distance.
You may desire a different field of coverage from the IR illuminator, if so the beam is focusable. 

By turning the lens of the IR illuminator you will change the beam width slightly.

NOTE:

 The IR will automatically turn off when the unit’s main power switch is turned to the “off” 

position.

SLEEP MODE

One of greatest new features, that your Smart scope has is a “SLEEP” mode. This feature will 

extend the life of your scope many folds, set the scope to memorize your initial settings and 

extend your battery life (by settings we mean only the digital settings. These include bright-

ness of the tube, brightness of the reticle, and magnitude of the IR. ) The sleep mode works in 

the following way:

The scope will automatically shut down if it dose not sense 

any activity for 20 minutes. Activity includes pressing any 

of the buttons ir simply moving it back and forth away from 

your face. When activating the sleep mode the scope will 

first warn you by turning off the reticle for 10 seconds. If 

your intention is to keep using the scope, simply touch any 

key and the scope will reactivate.
One of the reason why a “SLEEP” mode is programmed 

into your scope is to preserve the life of light intensifier tube 

and batteries in case you forget to turn your unit off. If you 

notice that the reticle has turned off after 20 minutes, just 

push “SL” button and the scope will return to its previous 

settings.
If you would like to put your scope in the “SLEEP” mode 

before the 20 minute period, just push the “SL” and “–” at the same time. Just push “SL” to 

return to previous settings, the “Smart” scope will remember them. This will be a very valuable 

feature if you are waiting for game to come, you could prepare all of the settings, place the unit 

in “SLEEP” mode and activate it precisely when you need it. To disable the proximity sensor 

press “SL” and “+” at the same time. In order to turn the proximity sensor back on, press” SL” 

and “+” at the same time again.

NOTE: 

The scope will be capable of running on “SLEEP” mode for more than 10 (ten) days and 

will be ready to use at any moment. Remember, you don’t have to turn the unit off while you are 

using it (“Smart” sight will remember all the settings. ) Use master “ON/OFF” switch only to store 

the scope. The proximity sensor will work best in a dark environment. Daylight testing and/or 

Infra-red illuminator

“SL” button

“-” button

“+” button

Summary of Contents for Aries MK

Page 1: ...AMERICAN TECHNOLOGIES NETWORK CORP u s e r s g u i d e Aries Mk 258...

Page 2: ...ies that may appear in this book 2001 ATN Corp All right reserved Master power switch Proximity sensor Manual focus Internal windage and elevation Infra red illuminator Control panel Mounts to standar...

Page 3: ...ontrol box light up Make sure to keep both eyes open and we suggest that you use your right eye for aiming through the scope This will give you a HUD Heads Up Display of the scope s functions while us...

Page 4: ...ess of the reticle and magnitude of the IR The sleep mode works in the following way The scope will automatically shut down if it dose not sense any activity for 20 minutes Activity includes pressing...

Page 5: ...lide out the eyepiece stop and make positive that the set screws are sufficiently loosened NOTE You do not have to remove the set screws completely they are very small and easy to misplace Now with a...

Page 6: ...the Aries scope entire mounting mechanism Tighten vertical fixator screws and horizontal fixator screws 5 Remount Aries 258 and tighten receptor attachment screws NOTE Receptor attachment screws may n...

Page 7: ...r Video camera s lens or your 35 mm camera s lens Loosen the three set screws on the camera adapter Place the camera adapter over the Aries Mk 258 s eyepiece Tighten the three set screws to fit snugly...

Page 8: ...certain that the pro tective glass surface of the sensor is always clean When the scope is first powered up the initial settings are Light intensifier tube Brightness 100 Reticle brightness 50 Illumi...

Page 9: ...e turn the unit off and wait 1 2 minutes before turning the unit back on Adverse atmospheric conditions such as fog smog or haze and a lack of ambient light moon or starlight may diminish the effectiv...

Page 10: ...de Video 35mm camera adaptable Superb multi coated 6 element lens system Manufactured exclusively by ATN Two year warranty SPECIFICATIONS Magnification 4 0x Intensifier Tube First gen hight res Lens S...

Page 11: ...articular purpose shall apply to the product All such implied warranties are hereby and expressly disclaimed LIMITATION OF LIABILITY ATN will not be liable for any claims actions suits proceedings cos...

Page 12: ...den Ave Suite 1B South San Francisco CA 94080 phone 800 910 2862 650 875 0130 fax 650 875 0129 European Office phone 44 0 870 0111286 fax 44 0 845 3349142 The following countries can use our toll free...

Reviews: