background image

Installation Instructions:

THE GUARANTEE IS SUBJECT TO CORRECT INSTALLATION.

The instant water heater is a novel appliance designed to supply hot water instantly while conserving energy. 

When the pressure switch is on, then the heating element heats the flowing water.

General information

1.  The appliance should be installed by a licensed electrician only.

2.  It is recommended that a residual current device (ELCB) will be incorporated in the  circuit.

3.  Installation of water pipeline must be completed prior to the installation of the heater and must be checked to 

assure that there are no water leaks.

4.  This  appliance  requires  water  pressure  of  minimum  0.3  bar  (4LB  /IN).  The  appliance  must  be  installed 

horizontally where water supply comes from the left side.

5. 

WARNING! You must use only the supplied outlet accessories. The water outlet should always be left 

open as the operating principle is based on an open water outlet.

6.  Without supervision the use of the appliance by young children or infirm person is forbidden.

  Playing with the unit by young children is forbidden. 

Installation of sink & shower unit 3kW - 9.5 kW  

1.  The shower unit should be installed above a person's height. (use installation chart)

2.  Remove cover in order to connect the electric cable to the terminal block inside the unit. (unscrew 4 screws)   
3.  The  unit should have a separate electric cable in the 

switch  board (see table 2)

4.  The recommended electric cable for 2-Phase unit up to 

9.5kW   is 5 x 4.0mm

2

5.  A 110V/5kW device must be connected to a separate 

40A fuse and a feeding cable of 3X6 mm

2

.

6.  Check  if  there  are  no  leaks  as  soon  as  the  unit  is 

connected.

  Use the hoses supplied with the appliance, do not re-

use old hoses

7.  After connecting the water inlet to the unit, connect the 

electric cable to the designed terminal blocks including 

grounding.

  WARNING! The appliance must be grounded

8.  The unit must be connected to the electric supply by a 

2-pole switch (for one phase unit) and to the multi-pole 

switch (in case of multi phase  unit)

9.  The main electric switch should be separated from the 

unit.

10. Connect the electric cable with the designated clamp.

11. Return the cover (4 screws) 

For effective use

1.  Open  the  water  faucet  (before 

inlet)  slowly  until  the  lights  in  the 

rocker switch are "ON". Wait 15-20 

seconds until hot water starts to flow. 

For colder water increase the water 

inflow  gradually  until  you  receive 

the desired water temperature. For 

hotter water please decrease water 

inflow.

2.  Heating position selector:

  0 - Shut Off

  1- Low (left light on)

  2 - Medium (Right light on)

  3 - High (both lights on)

3.  In  order  to  achieve  maximum 

efficiency from the unit please grip 

the shower head and twist it in either 

direction,  operating  rings  installed 

in  shower  head  can  be  changed 

according  to  season,  summer  or 

winter position

  (Fig.1 & Fig.2).  An additional ring 

set is supplied with the unit for head 

set 1  (Fig.1a).

  For sink unit - Install open rings in 

summer  and  blind  rings  in  winter 

(inner  ring  should  remain  always 

open) (Fig.3).

4.  The spray outlet should be cleaned 

periodically by unscrewing it from the 

shower head and clean thoroughly. 

(Fig.1a, Fig.2a, Fig.3)

5.  The unit operates automatically by 

opening the water faucet and shut 

off when closing the water supply.

4 Setting 

Spray 

Positions

screws

screws

screws

screws

Power

selections

Power

selections

Incorrect:

Danger:

Do not install a faucet

at the water outlet

Danger!!!

Incorrect Installation

Incorrect Installation

Water 

Inlet

Faucet

Cable 

Entry

Inlet

Inlet

Outlet

Outlet

2 Rails

Bottom Cover

(New Model Only)

Winter Position

Fig. 1

Fig. 2

Winter 

Set 

Rings

Fig. 3

Water

Outlet

Correct Installation

Sink

Shower

Position

Selector

New

Basic

Winter Set Rings

Reviews: