![Atmel STK511 User Manual Download Page 35](http://html.mh-extra.com/html/atmel/stk511/stk511_user-manual_3003507035.webp)
Troubleshooting Guide
7-2
STK511 User Guide
4842B–AVR–10/09
Registers in the receiver do not
appear to be programming
Power supplied is too low
Verify that the power being supplied
is 5V
DATA Selector switch was not set to
the STK511 position when
Configure button pressed
Set DATA Selector switch to
STK511 and re-press button
Receiver Interface Board firmware
has become corrupted
Reload the Receiver Interface
Board Firmware as described in
section
Registers may be programming
correctly with no visible signs of
change
Monitor the Data Testpoint with an
oscilloscope to check for presence
of the acknowledge bit
Some external source may be
holding the Data line low
Receiver Application Board rotated
180° when mounted on the
Receiver Interface Board
Verify that Receiver Application
Board signal testpoints are toward
the DIP switches.
Unable to load Receiver Interface
Board firmware
Receiver Interface Board not
correctly connected to STK500
Verify EXPAND0 and EXPAND1 are
properly oriented
ISP ribbon cable not connected
properly
Ensure ribbon cable connected
between ISP6PIN header and
SPROG3 header
Check orientation of pin 1 on
headers
Incorrect device selected
Select ATmega8515 from the
Device menu. Verify that the
signature byte matches in the
Advanced tab
Device present in STK500 sockets
Remove all devices from the
programming sockets of the
STK500
ISP jumper not shorted on Receiver
Interface Board
Connect shunt
Power and serial cable not
connected to STK500
Verify setup of the STK500
hardware
Transmitter not responding to
button press
Battery dead
Open Transmitter Application Board
case and replace coin cell battery
Demo Software corrupted
Reload the desired software
according to section
Switch contact not made
Ensure proper contact of the button
to the Transmitter Application Board
No activity on Transmitter
Application Board LED(s)
Low Battery voltage
Replace coin cell battery
Transmitter is in sleep mode
Press button to wake from sleep
mode
Demo Software corrupted
Reload the desired software
according to section
Table 7-1. Troubleshooting Solutions (Continued)
Problem
Reason
Solution