Atmel REB231ED Quick Start Manual Download Page 2

 

Atmel AVR2040 

8381B-AVR-09/11 

OFF 
  Power switch
ON 

 

 
 

Plug each REB vertically into the 2x20 female Expand1 connector header on the 
CBB: 

  Ensure that the pin 1 marking on the REB header aligns with the corresponding 

pin 1 marking on the CCB Expand1 connector header 

  The top side of the REB, which has the radio transceiver and antenna, should be 

facing towards the batteries on the CBB 

3 Simple range measurement 

The pre-flashed performance test suite on the REB231ED evaluation kit assemblies 
features a simple range measurement application. Each assembly operates in a 
standalone manner, and is able to transmit or receive data frames. A successful 
transmit or receive operation is indicated by a blinking LED. 

3.1 Power up the assemblies 

Apply power to both REB-CBB assemblies 
by switching on the power switch located on 
the top side of the CBB. The assemblies run 
a power-on check, and indicate the 
successful completion by switching on the 
second of the three LEDs, LED-D2. 

3.2 Run simple range measurement application 

Choose one of the REB-CBB assemblies, and press button T1 
to start the simple range measurement application. 

First, the REB-CBB initiates a connection and configuration 
procedure by sending broadcast frames and waiting for a 
response from the second REB-CBB. After a successful 
configuration, the REB-CBBs turn on LED-D1 to indicate that 

status. Afterwards the initiator starts to transmit data frames immediately. Each data 
frame transmission is indicated by blinking the TX status LED-D2. A successful data 
frame reception on the second node is indicated by blinking the RX status LED-D3. 
The RX status LED stops blinking if no data frames are received, such as when, for 
example, the node has left the communication range. Data frame transmission can be 
stopped by pressing T1 once more on the node transmitting frames. 

Moreover the REB-CBBs can transmit and receive frames simultaneously. Pressing 
button T1 on both nodes initiates each node to transmit frames. The three LEDs 
indicate their respective functions: LED-D1 a successful configuration, LED-D2 
transmission and LED-D3 reception. 

NOTE 

The node configuration gets lost when resetting or switching off the REB-CBB power 
supply. To restart the simple range measurement, a reset or power cycle has to be 
applied to both REB-CBB assemblies before pressing T1 on one (or both) REB-
CBB(s) to restart the application. 

4 Packet error rate measurement 

The pre-flashed performance test suite is also configured with packet error rate (PER) 
measurement functionality (as defined in IEEE

®

 802.15.4), enabling the user to 

explore various radio transceiver features, radio transceiver registers, and 
performance by tuning with customized configurations. For this application, one REB-
CBB needs to be connected to a PC. 

 

D3    D2    D1       T1

RX    TX    configuration 
                   status

Reviews: