CAMELIA 1.6M user guide
12/14
2.8 E
NVIRONMENTAL REQUIREMENTS
♦
operating temperature : 0°C / +50°C
♦
storage temperature : -20°C / 70°C
♦
operating humidity : < 80% at +35°C
♦
vibration : 2g sinusoidal, from 10Hz to 100Hz.
3. CONNECTORS AND CABLES
3.1 ‘’D
ATA AND SYNC
’’
CONNECTOR
50 points 3M connector.
♦
connector reference :HIROSE DX10A-50S.
♦
mating connector on cable side : HIROSE DX40-50P ; shell : HIROSE DX50-CV1.
Pin-out :
Pin n°
Signal
Pin n°
Signal
1
PCK+
26
LEN+
2
PCK-
27
LEN-
3
FEN+
28
CO (1)
4
FEN-
29
COLOUR_O1-(1)
5
CO (1)
30
GROUND
6
COLOUR_O2-(1)
31
GROUND
7
32
8
PDATA0-
33
PDATA1-
9
34
10
PDATA2-
35
PDATA3-
11
36
12
PDATA4-
37
PDATA5-
13
38
14
PDATA6-
39
PDATA7-
15
40
16
PDATA8-
41
PDATA9-
17
42
18
PDATA10-
43
PDATA11-
19
GROUND
44
NC
20
GROUND
45
NC
21
46
T
22
SHUTTER-
47
TRIG_ITC-
23
CO(1)
48
CO(1)
24
COLOUR_I1-(1)
49
COLOUR_I2-(1)
25
NC
50
NC
Notes :
◊
NC : not connected.
◊
(1) : grey cells : not used for CAMELIA COLOR : must be left unconnected
◊
a "Data + Sync" cable is provided with FGT Frame grabber, including a part to be connected to the
electro-optical interface, and the second one to the "FGT" frame grabber : see "FGT Frame Grabber user
manual".