Back Panel
1. FW port - USB not enabled at this time for future functionality
2. Main system control - Connect IR or RS-232 control system to the matrix
3. LAN port - Connect to a network for TCP/IP, WebGUI, and firmware updates
4. HDMI input - Connect HDMI sources to these ports
e.g.
DVD players, Blu-ray players, computers, game consoles, etc
5. Extended distance HDBaseT port - Connect to extended distance EX receivers for pass through
of PoE, control, and A/V signals.
e.g.
AT-UHD-EX-100CE-RX
6. Long distance HDBaseT ports - Connect to long distance EX receivers for pass through
of PoE, control, and A/V signals.
e.g.
AT-UHD-EX-70C-RX
7. HDMI output - Mirror to provide a local output for HD audio routing to an AVR, or matrix the
port to provide a local video output for an in room display or an HDBaseT extender set
e.g.
AT-UHD-EX-100CE-KIT or AT-UHD-EX-70C-KIT
8. Audio out - Captive screw analog audio breakouts for use with a sound system or multi-channel
zone amplifier -
Audio outputs follow the corresponding HDBaseT outputs
e.g.
Audio out 1 follows HDBaseT 1
9. IR IN - Use with a 3rd party IR control box to extend IR control commands to video displays over
category cable
10. IR OUT - Connect IR emitter here for controlling sources
11. Internal power supply - Connect included IEC C13 power cable from here to a power outlet.
To rack mount the UHD-PRO3-
44M unit: use the rack mount
ears, the 4 screws from the sides
of the UHD-PRO3-44M, and 4
rack screws.
To affix the rack mount ears,
remove the three screws on each
side of the UHD-PRO3-44M and
affix the rack ears to the UHD-
PRO3-44M
(as shown in the picture to
the left)
.
Place the UHD-PRO3-44M in the
rack, lining the holes in the rack
ears with the holes in the rack.
Once placed, use the rack screws
to keep the unit in place.
(as shown
in the picture to the left)
Note:
Increase the air flow as needed to
maintain the recommended
temperature inside the rack.
Note:
Do not exceed maximum weight
loads for the rack. Install heavier
equipment in the lower part of the
rack for stability.
4
6
5
7
3
2
8
9
1
10
11
POWER
ENTER
CANCEL
INFO
EDID
FNC
5
1
2
3
4
POWER
ENTER
CANCEL
INFO
EDID
FNC
5
1
2
3
4
Rack Mounting