9
atlona.com
Toll free: 1-877-536-3976
Local: 1-408-962-0515
To
save
an I/O route to memory
To
load
a saved I/O route
Feedback
=
”Memory # saved”
Feedback
=
”Memory # loaded”
--->
--->
--->
--->
--->
--->
--->
--->
--->
--->
--->
--->
--->
--->
--->
--->
--->
--->
AT-PRO3HD44M
Select Input Number
AT-PRO3HD44M
Select Input Number
Select Function Option
Select Function Option
1 Save in/out route
2 Select memory route
1 Save in/out route
2 Select memory route
Save to memory (1-4) #
Press enter
Select Memory route 1-4
Press enter to load
home screen
home screen
memory selection
memory selection
Once inputs and outputs have been set they can be saved to memory and recalled later. Up to 4
individual input/output routes can be saved. The route will remain in memory until a new route has
been saved to that memory number or the matrix has been factory reset.
Once an input/output route has been saved, it can be loaded at any time.
I/O Route Memory
O: 1 2 3 4
I : 4 2 1 3
example route
When the matrix is completely connected and turned on it will load the
default EDID
, which is the
highest common native resolution of the devices. (
i.e. In the diagram below the default would be
720p with 2ch audio.
Multi-channel audio and 3D are not enabled on internal mode, unless
all devices have these features.
)
EDID S
et Up
Output 2
Output 3
Input 2
1080p-Dolby TrueHD (3D)
Input 1
Output 1
720p-2ch
720p-2ch
1080p (3D)-2ch
1080p-Dolby TrueHD (3D)
AT-PRO3HD44M
DC 24V
ZONE 4
ZONE 3
ZONE 2
ZONE 1
HDMI IN
MATRIX OUT
RS-232
LAN
MATRIX IN
IR IN
IR OUT
COAX
OUT
CAT5e/6/7
IR IN
IR OUT
COAX
OUT
CAT5e/6/7
IR IN
IR OUT
COAX
OUT
CAT5e/6/7
IR IN
IR OUT
COAX
OUT
CAT5e/6/7
1
2
3
4
AT-PRO3HD44M
ENTER
POWER
EDID
MEMORY
ALL
DEFAULT
CANCEL
FUNCTION
1
2
3
4
On default, all devices in the diagram will work at 720p. If a device is not syncing or a different
resolution is required, internal EDID or EDID copy and load should resolve these issues. The