background image

AT-OPUS-RX41

43

4. 

Mount the unit to a flat surface using the oval-shaped holes, on each mounting bracket.  If using a drywall 

surface, a #6 drywall screw is recommended.

The AT-OPUS-RX41 includes two mounting brackets, which can be used to attach the unit to any flat surface.

 

Use the two enclosure screws, on the sides of the unit, to attach the mounting brackets.

1.  Using a small Phillips screwdriver, remove the two screws from the left side of the enclosure.

1

2

3

4

INPUT

INPUT

POWER

FW

AT-OPUS-RX41

OPUS

TM

1

2

3

4

INPUT

INPUT

POWER

FW

AT-OPUS-RX41

OPUS

TM

1

2

3

4

INPUT

INPUT

POWER

FW

AT-OPUS-RX41

OPUS

TM

NOTE:

 Mounting brackets can also be inverted to mount the unit under a table or other flat surface.

Appendix

Mounting Instructions

2. 

Position one of the mounting brackets, as shown below, aligning the holes on the side of the enclosure with one 

set of holes on the mounting bracket.  Use the screws from Step 1 to attach the mounting bracket.

3. 

Repeat steps 1 and 2 to attach the second mounting bracket to the opposite side of the unit.

Summary of Contents for AT-OPUS-RX41

Page 1: ...AtlonaManuals Switchers AT OPUS RX41 4x1 4K HDR Switcher and Receiver with HDMI and HDBaseT Inputs ...

Page 2: ...AT OPUS RX41 2 Version Release Date Notes 1 Dec 2020 Initial release Version Information ...

Page 3: ... to http www atlona com registration Sales Marketing and Customer Support Welcome to Atlona Operating Notes IMPORTANT Visit http www atlona com product AT OPUS RX41 for the latest firmware updates and User Manual Main Office Atlona Incorporated 70 Daggett Drive San Jose CA 95134 United States Office 1 877 536 3976 US Toll free Office 1 408 962 0515 US International Sales and Customer Service Hours...

Page 4: ...ms New Products 10 years from proof of purchase date for hardware electronics products purchased on or after June 1 2013 3 years from proof of purchase date for hardware electronics products purchased before June 1 2013 Lifetime Limited Product Warranty for all cable products Limited Product Warranty Terms Refurbished B Stock Products and Discontinued Products 3 years from proof of purchase date f...

Page 5: ...ts or states do not allow the exclusion or limitation of relief special incidental consequential or indirect damages or the limitation of liability to specified amounts so the above limitations or exclusions may not apply to you Exclusive Remedy To the maximum extent permitted by law this limited product warranty and the remedies set forth above are exclusive and in lieu of all other warranties re...

Page 6: ...ot block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install or place this product near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of a polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding t...

Page 7: ... 21 Using the Web Server 21 Physical Input Switching 21 HDCP Settings 22 Controlling Audio 23 HDMI Output Muting 23 Optical Output Muting 23 Using the Audio Return Channel ARC 24 Switching between ARC and HDMI inputs 26 Managing Users 27 Adding Users 27 Editing Deleting Users 28 Resetting to Factory Defaults 29 Using the Front Panel 29 Using the Web Server 29 HDBaseT Testing 31 Configuration and M...

Page 8: ...AT OPUS RX41 8 Table of Contents Appendix 41 Updating the Firmware 41 Using the Web Server 41 Using USB 42 Mounting Instructions 43 Specifications 44 ...

Page 9: ...the local TOSLINK connection as well as HDBaseT EDID management selectable 4K to 1080p downscaling and HDCP 2 2 support with selectable down conversion to HDCP 1 4 ensures compatibility with legacy displays Remote power allows the device to be powered by an Opus matrix switcher for installation flexibility at a display or projector Introduction Features Package Contents 4 1 switcher with three HDM...

Page 10: ...NPUT HDBaseT Connect a category cable CAT 5e or better from this port to a compatible HDBaseT transmitter This category cable provides both data transfer and can be used to power the AT OPUS RX41 7 INPUT HDMI Connect an HDMI cable from each of these ports to an UHD HD source 8 HDMI OUT Connect an HDMI cable from this port to a display or other sink device This output supports multichannel audio 9 ...

Page 11: ...Output 1 toggle switch in the Web Server will also be updated to reflect the current muting state Refer to A V Settings page page 33 for more information SW R1 Video 1 Video Video 2 All On Power Vol Vol Mute 1 3 2 4 5 Input Audio On Off On Off On Off The AT OPUS RX41 includes an IR remote control unit allowing the control of the AT OPUS RX41 from a remote location Always make sure that the IR remo...

Page 12: ...ed captive screw connector included in the box 2 Use wire strippers to remove a portion of the cable jacket 3 Remove at least 3 16 5 mm of insulation from each of the wires 4 Insert the wires into correct terminal Refer to Figure 1 1 or Figure 1 2 below 5 Connect the captive screw block to the proper port OPTIONAL RX TX TX RX INPUT 4 3 2 1 HDMI OUT DC 5V LAN RX S TX RS 232 IR IN OPTICAL HDBaseT RS...

Page 13: ...Remove at least 3 16 5 mm of insulation from each of the wires 4 Insert the wires into correct terminal Refer to Figure 1 1 Figure 2 2 or Figure 1 2 below 5 Connect the captive screw block to the proper port Figure 2 1 Wiring the 5 pin HDBaseT RS 232 IR captive screw block to have a controller at the viewing location send IR commands over HDBaseT to an IR emitter Figure 2 3 Wiring the 4 pin HDBase...

Page 14: ...R and 4K 60 4 4 4 content HDMI data rates exceeding 10 Gbps the AT OPUS RX41 is not compatible with transmitters for the AT HDR EX 70 2PS AT HDR EX 70C KIT or AT HDR EX 100CEA KIT 1 2 3 4 INPUT INPUT POWER FW AT OPUS RX41 OPUSTM OPTIONAL RX TX TX RX INPUT 4 3 2 1 HDMI OUT DC 5V LAN RX S TX RS 232 IR IN OPTICAL HDBaseT RS 232 IR 1 2 3 4 5 6 7 8 3 Connect an HDMI cable from the HDMI OUT port to a UH...

Page 15: ... Player AT OPUS 46M 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 AUDIO IN 1 2 1 2 3 4 5 6 7 8 9 10 LAN DEBUG IRIN RS 232 RX S TX R L R L AUDIO OUT R L R L R L R L R L R L R L R L R L R L 1 2TOSLINK IN 3 4 1 2 3 4 5 6 7 8 9 10 TOSLINK OUT IRIN IROUT S S S S S S S S S S S S S S S S S S ON 1 2 3 4 5 6 7 8 1 2 3 4 5 6 PoE LINK HDBaseT OUT 7 8 HDMI OUT 9 10 CHASSIS GROUND PoE LINK PoE LINK PoE LINK PoE LINK Po...

Page 16: ...OPUS RX41 is 192 168 1 254 If the AT OPUS RX41 is unable to detect a DHCP server within 15 seconds then the unit will set all IP settings to zero 1 Make sure the AT OPUS RX41 is powered 2 Connect an Ethernet cable between the LAN port of the AT OPUS RX41 and the Local Area Network LAN 3 Press and hold the INPUT button on the front panel for approximately 20 seconds Release the INPUT button once th...

Page 17: ...s by the DHCP server if present The System page page 38 in the Web Server allows the AT OPUS RX41 to use either DHCP or static IP mode In order to access the Web Server the IP address of the AT OPUS RX41 must be known Refer to Web Server Login page 20 for more information 1 Open the desired web browser and enter the IP address of the AT OPUS RX41 2 Log in using the required credentials The factory...

Page 18: ...tor on the rear of the unit Make sure that the power supply is connected to an available electrical outlet and that the outlet is live some outlets are controlled by a wall switch Blue flashing backlight 4x Flashes four times to indicate that the unit is set to DHCP mode Refer to IP Configuration page 16 for more information Blue flashing backlight 2x Flashes two times to indicate that the unit is...

Page 19: ...put and is indicated by the INPUT 2 LED indicator on the front panel 2 Press the INPUT button again to switch to INPUT 3 Once INPUT 4 is selected and the INPUT button is pressed again the unit will return to INPUT 1 Manual input switching can also be performed under the A V Settings page page 33 of the Web Server by clicking the Input Selection drop down list and selecting the desired input In add...

Page 20: ...41 If a static IP address is desired refer to IP Configuration page 16 The default static IP address of the AT OPUS RX41 is 192 168 1 254 1 Launch a web browser 2 In the address bar type the IP address of the AT OPUS RX41 3 The Login page will be displayed 4 Type admin using lower case characters in the Username field 5 Type Atlona in the Password field This is the default password The password fi...

Page 21: ...ear panel The AT OPUS RX41 will automatically switch to the port with the connected source The following rules apply to auto switching If a source is disconnected then the AT OPUS RX41 will fallback to a port with an active source If all sources are disconnected then the AT OPUS RX41 will retain the port of the last connected source Auto switching can also be used to automatically select an input ...

Page 22: ...P address of the AT OPUS RX41 2 Log in as the admin user with the required credentials The factory default username and password for the admin user are listed below Username admin Password Atlona 3 Click A V Settings in the menu bar 4 Click the drop down list next to the HDMI input that is connected to the source and set it to the Noncompliant This will instruct the source device to send non HDCP ...

Page 23: ... admin Password Atlona 3 Click A V Settings in the menu bar 4 Locate the Audio section 5 Click the Output 1 toggle switch to the MUTE position When set to the MUTE position the audio on the HDMI OUT port will be muted To re enable the audio for the HDMI OUT output set the toggle switch to the UNMUTE position 1 Open the desired web browser and enter the IP address of the AT OPUS RX41 2 Log in as th...

Page 24: ...uctions on the following page will reference the diagram below Ge ne ric SPEA KER SYST EMS Ge ne ric SPEA KER SYST EMS Gen eric SPEAKE R SYSTEM S AT OPUS RX41 HDMI Audio Display A V Receiver Speaker System SOURCE DVD AA X DE C BN E XO R Gen eric SPEAKE R SYSTEM S Gen eric SPEAKE R SYSTEM S Ge ne ric SPEA KER SYST EMS POW ER INP UT FW 1 2 3 4 INP UT AT OPU S R X41 JUN OX TM NOTE Some displays limit...

Page 25: ...o the ARC position The default setting is SPDIF 8 Set the Toslink toggle switch to the ON position and the Output 1 toggle switch to the UNMUTE position 9 Setup is complete Audio from the display will now be heard over the A V receiver To disable ARC and hear the audio from the HDMI inputs set the HDMI input audio breakout toggle switch to the SPDIF position Refer to the next page for information ...

Page 26: ...ation If controlling over IP connect an Ethernet cable from the control system to the LAN port on the AT OPUS RX41 Refer to the control system user manual for any necessary configuration details 2 Send the AudioSRC command to set the desired operation AudioSRC ARC enables ARC only audio from the downstream display is output to the OPTICAL OUT port AudioSRC SPDIF disables ARC HDMI inputs are enable...

Page 27: ...y default username and password for the admin user are listed below Username admin Password Atlona 3 Click the Config tab 4 Click the Add button under the Edit column 5 Enter the desired username and password in the Username Password Edit dialog box 6 Click the Save Change button to commit changes or click the Cancel button to return to the Config page without adding the user Once created the new ...

Page 28: ... Atlona a Click Config in the menu bar b Click the Edit button next to the user to be changed c Enter the new information for the user in the Username Password Edit dialog box d Click the Save Change button to commit changes or click the Cancel button to return to the Config page without making changes a Click the Remove button next to the user to be deleted The username and password of a user can...

Page 29: ...Simultaneously press and hold the POWER and INPUT buttons for more than 15 seconds 3 Release both buttons 4 The factory reset process is complete Resetting to Factory Defaults Using the Front Panel Using the Web Server 1 Open the desired web browser and enter the IP address of the AT OPUS RX41 2 Log in as the admin user with the required credentials The factory default username and password for th...

Page 30: ...e displayed at the top of the screen Click OK to continue with the factory default reset procedure Click Cancel to abort the process 6 Once the factory default process is complete the Web Server Login screen will be displayed 7 The factory reset process is complete ...

Page 31: ...re information if necessary 2 Click HDBT in the top menu bar 3 Make sure that a category cable CAT 5e or better is connected between the INPUT 1 HDBaseT port and a compatible transmitter 4 Click the Start button to begin testing the selected channel If the HDBaseT link integrity is good then all tests will display as Pass If any part of the HDBaseT cable fails then a numerical value in decibels wi...

Page 32: ...ng the PWOFF command will not reset this field Active Input The currently selected input The active input can be changed under the A V Settings page page 33 or by pressing and releasing the INPUT button on the front panel Signal Type Displays the input resolution of the source device Video Format Displays the video format Aspect Displays the aspect ratio of the input video source Color Space Displ...

Page 33: ...t input The default setting is ON HDCP Settings Sets the HDCP reporting mode of the specified HDMI port Input 1 INPUT 1 HDBaseT Input 2 INPUT 2 Input 3 INPUT 3 Input 4 INPUT 4 Some devices will transmit HDCP content if an HDCP compliant display sink is detected Setting this value to OFF will instruct the source to send non HDCP content if possible to non HDCP display and or sink devices Note that ...

Page 34: ...of the unit ARC Audio being returned from the display over ARC will be output on the OPTICAL port on the AT OPUS RX41 It should be noted that the audio is limited to formats supported by the SPDIF output such as PCM Dolby Digital and some formats of DTS Lossless audio formats such as Dolby TrueHD and DTS HD Master Audio are not supported by ARC or SPDIF Scaler Pass Through Click this toggle switch...

Page 35: ... 38400 56000 57600 115200 Data bit Sets the number of data bits used to represent each character of data The following options are available 7 or 8 Parity Sets the parity bit which can be included with each character to detect errors during the transmission of data The following options are available None Odd or Even Stop bit Sets the stop bit Stop bits are sent at the end of each character allowi...

Page 36: ...am EDID Eight memory locations are available Once an EDID is saved to a memory location it can be access from the EDID Settings drop down lists EDID listing Default 1920x1200 DVI 1080P 2CH 3840x2160 60 4 2 0 2CH 1080P MCH 3840x2160 60 4 2 0 MCH 1080P DD 3840x2160 30 4 4 4 2CH 1080P 3D 2CH 3840x2160 30 4 4 4 MCH 1080P 3D MCH 4096x2160 60 4 2 0 2CH 1080P 3D DD 4096x2160 60 4 2 0 MCH 720P 2CH 3840x21...

Page 37: ...d Enter the new password for the admin username in this field Confirm New Password Verify the new password by retyping it in this field Username Displays the username Password Displays the password for the associated username Edit Click the Add button in this column to edit the username and password in the row Del Click the Remove button to delete the user in the row This button will only be avail...

Page 38: ... Enter the Telnet listening port in this field Telnet Login Mode Click this toggle to set the login mode to either ON or OFF If this feature is set to ON then the AT OPUS RX41 will prompt for both the username and password at the start of a Telnet session Use the same credentials as the web server Telnet Timeout Click this drop down list to select the timeout interval in seconds before the Telnet ...

Page 39: ...ck Set this toggle to the LOCK position to prevent the AT OPUS RX41 from being powered off if the POWER button is accidentally pressed By default this is set to UNLOCK Reset to Default Click the Factory Default button to set the AT OPUS RX41 to factory default settings Firmware Update Click the Choose File button to select the firmware file when upgrading the firmware on the AT OPUS RX41 Once the ...

Page 40: ... Error Rate BER and cable test results TX Version The version of the Valens chip on the transmitter RX Version The version of the Valens chip on the receiver TMDS Clock Displays the pixel clock speed If no source is connected then this field will display as None Cable length Estimated This field indicates the approximate length of the Ethernet cable connected between the HDBaseT port on the AT OPU...

Page 41: ...ect an Ethernet cable from the computer containing the firmware to the same network where the AT OPUS RX41 is connected 2 Go to the System page page 38 in the Web Server 3 Click the Choose File button under Firmware Update 4 Browse to the location of the firmware file select it and click the Open button 5 Click the Update button to begin the update process 6 The following message box will be displ...

Page 42: ...B cable between the PC and the firmware port on the AT OPUS RX41 The unit will be powered by the USB cable 5 The USB UPDATE folder will be displayed If this folder is not displayed automatically select the USB UPDATE drive from Windows Explorer Appendix Using USB 7 Delete all files from the USB UPDATE drive if any are present 8 Drag and drop the firmware file to the drive During the firmware updat...

Page 43: ...e left side of the enclosure 1 2 3 4 INPU T INPU T PO WER FW AT OPU S RX 41 OPUS TM 1 2 3 4 INPU T INPU T PO WER FW AT OPU S RX 41 OPUS TM 1 2 3 4 INPU T INPU T PO WER FW AT OPU S RX41 OPUS TM NOTE Mounting brackets can also be inverted to mount the unit under a table or other flat surface Appendix Mounting Instructions 2 Position one of the mounting brackets as shown below aligning the holes on t...

Page 44: ...60 60 50 30 25 24Hz 1080p 60 59 9 50 30 29 97 25 24 23 98Hz 1080i 30 29 97 25Hz 720p 60 59 94 50Hz 576p 50Hz 576i 25Hz 480p 60 59 96Hz 480i 30Hz VESA All resolutions are 60Hz 2560 1600 2048 1536 1920 1200 1680 1050 1600 1200 1440 900 1400 1050 1280 1024 1280 800 1366 768 1360 768 1152 864 1024 768 800 600 640 480 Color Space YUV RGB Chroma Subsampling 4 4 4 4 2 2 4 2 0 Color Depth 8 bit 10 bit 12 ...

Page 45: ...arrel connector locking Power Consumption 6 6 W Idle Consumption 5 9 W Supply Input AC100 240V 50 60Hz Output DC 5V IR Port 1 x 4 pin captive screw local 1 x 5 pin captive screw HDBaseT Frequency Range 30 kHz to 60 kHz CEC Port HDMI Type A 19 pin female Triggering Through IP RS 232 and built in web server Dimensions H x W x D Inches Millimeters Unit 1 0 x 8 6 x 5 9 26 x 219 x 152 Power Supply AT P...

Page 46: ...d names and trademarks or registered trademarks are the property of their respective owners Pricing specifications and availability subject to change without notice Actual products product images and online product images may vary from images shown here Toll free US International atlona com 877 536 3976 41 43 508 4321 ...

Reviews: