www.atlona.com | toll free:
1-877-536-3976
For International: 1-
408-962-0515
9
8.4. RS-232 Protocols
8.4.1. Pin Assignment
AT-HD-V88M
Remote Control Console
PIN
Assignment
PIN
Assignment
1
NC
1
NC
2
Tx
2
Rx
3
Rx
3
Tx
4
NC
4
NC
5
GND
5
GND
6
NC
6
NC
7
NC
7
NC
8
NC
8
NC
9
NC
9
NC
Baud Rate: 19200bps
Data bit: 8 bits
Parity: None
Flow Control: None
8.4.2. Commands
COMMAND
ACTION
POWER 00
Power Off (standby)
POWER 01
Power On
PORT 11
Output A select Input1
PORT 12
Output A select Input2
PORT 13
Output A select Input3
PORT 14
Output A select Input4
PORT 15
Output A select Input5
PORT 16
Output A select Input6
PORT 17
Output A select Input7
PORT 18
Output A select Input8
PORT 21
Output B select Input1
PORT 22
Output B select Input2
PORT 23
Output B select Input3
PORT 24
Output B select Input4
PORT 25
Output B select Input5
PORT 26
Output B select Input6
PORT 27
Output B select Input7
PORT 28
Output B select Input8
PORT 31
Output C select Input1
PORT 32
Output C select Input2
PORT 33
Output C select Input3
PORT 34
Output C select Input4
PORT 35
Output C select Input5