9.2 Measurement result
Move the wheel manually until all the LED’s corresponding to the side light up. The display shows the
measured unbalance. Pressing the chuck can be locked/released in any position to facilitate mounting
the wheel (see
MENU
).
For unbalance within tolerance
0 (zero)
; using values within tolerance can be viewed.
After positioning and locking the wheel, apply the weight vertically at the top.
9.3 Static unbalance
It is selected by pressing and is shown on the central display. The position is indicated on the displays 3
and 4.
9.4 Exact positioning of the adhesive weight by means of the gauge with clips
▪ Press if using the correction method with adhesive weights on the inside of the rim
FI
FE
▪ Fit the correction weight in the specific gauge seat with the adhesive part facing upwards
▪ Bring the wheel into correct angular position for the plane to be corrected.
▪ Pull the gauge further outwards.
▪ Return the gauge to the rest position.
▪ When the weight application distance has been reached a beep is sounded (can be deactivated)
▪ Rotate the gauge until the correction weight adheres to the rim
▪ the fact that the weight application position is no longer vertical is automatically compensated
INDICATION
The approach of the weights to the correction positions is indicated by the LEDs number 18