AtlasSound.com
– 10 –
Owner’s Manual
PA40G / PA60G
Commercial Amplifiers
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
Specifications
Type
Commercial Amplifier
Safety Listings
TUV UL60065 Standard, CE, Class 3 Rated
Electrical Specifications
Power Output
PA40G: 40W @ 70.7V (125
Ω
), 40W @100V (250
Ω
)
PA60G: 60W @ 70.7V (83
Ω
), 60W @ 100V (166
Ω
)
Front Panel
Indicators
Power, Limit, Signal
Controls
Input 1 Gain
Technical Data
Frequency Response
50Hz - 20kHz
Thd+N
.5% or Less @ 1kHz, Rated Output
Sensitivity
Line Input 500mv (600
Ω
)
Inputs 2 / 3 RCA 500mv (10k
Ω
)
Output Regulation
Less Than 2dB, No Load To Full Load
Signal To Noise Ratio
Balanced Input = >55dB
Unbalanced RCA Summed = >55dB
Power Requirements
Power Consumption
PA40G: Idle: 0.075A, 8W, 27 BTU
Average: 0.26A, 24W, 81 BTU
Max: 0.8A, 71W, 242 BTU
PA60G: Idle: 0.075A, 8W, 27 BTU
Average: 0.41A, 34W, 116 BTU
Max: 1.25A, 102W, 348 BTU
Fuse
PA40G: T630mA
PA60G: T1A
Mechanical
Dimensions
8.5" x 1.75" x 7.81" (216mm x 45mm x 198mm)
Weight
PA40G: Net Weight = 2.9lbs. (1.32kg), Shipping Weight = 3.1lbs. (1.4kg)
PA60G: Net Weight = 2.9lbs. (1.32kg), Shipping Weight = 3.1lbs. (1.4kg)
Note:
Average power consumption is based on one third (1/3) of the maximum power rating, 50% duty cycle.