8.  four Position dip switch Assignment
 

switch 1 - sense on/off

, this switch activates the PA1001G remote turn on sensing circuits via either Audio or 

AC trigger. When the switch is in the “

doWn” position, all trigger circuits are bypassed. The only way to turn the 

amp On or Off is via the mains AC Power Switch located on the front panel. When in the “

uP” position either the 

Audio or AC Sense turn on Triggers is activated. See switch 2 for selection.

 

switch 2 - sense Ac / Audio

, when Switch 1 is in the “

uP” position you may select the type of remote turn on 

trigger. Note the AC Mains Power Switch must also be in the “

on” position.

 

Ac trigger

 - This switch function is used if you have an external device is plugged into the Unswitched AC outlet 

and you want that device to turn on or activate the amplifier. The “

uP” position of Switch 2 is for AC trigger, meaning 

if a device such as a projector is plugged into the Unswitched AC outlet and is turned on the AC trigger circuitry 
will sense current draw and turn on the PA1001G. Note: To trigger the AC sense circuity you need a minimum of a 
100mA of current draw to activate the PA1001G.

 

Audio trigger

 – This switch function is used if you have an external audio source plugged into either the RCA or 

Balanced inputs and you want that audio to turn on or activate the amplifier. If Switch 2 is in the “

doWn” position it 

is in Audio Sense mode. When audio is present at either the RCA or Balanced inputs, the trigger circuitry will turn on 
the PA1001G. See Audio Sense control below for sensitivity adjustments.

 

switch 3

 – Line Out Pre - Post VCA - This switch function works in conjunction with the Line Out Jack and the 

Remote Level Control feature. This switch determines if the Line Out signal is fixed (Pre) or works with the Remote 
Level Control (Post). The “

doWn” position is Pre Remote Level, meaning the Remote Level does not affect the 

signal of the Line output and the “

uP” position is Post or after the Remote Level Control, meaning the level will 

change with the Remote Level Control.

 

switch 4

 – Hi Pass Filter In / Out, when this switch is in the “

uP” position no input filter is applied. With the switch 

in the “

doWn” position a 100Hz 12db Hi-Pass filter is engaged at the input of each channel.

9.  Audio sense trigger Adjustment

 

This potentiometer works when Dip Switch 1 is set to “

doWn” or “sense on” position and Dip Switch 2 is in the 

uP” or “Audio” position. By rotating the potentiometer clockwise (right) the trigger point becomes less sensitive to 

turn on, meaning it will take more audio signal at the input to turn on the amp. Note: Once the PA1001G has sensed 
audio signal and has triggered on, it will take15 -20 min for it revert back into sleep mode even when there is no 
audio present. The PA1001G level controls have no affect on this feature.

10.  line level out 

This unbalanced RCA output allows you to feed the audio signal from the PA1001G amplifier to another amplifier. 
You can select to have a fixed signal or you can assign it to work with the Remoter Level Control. See Line Out 
Function Switch for settings.

11.  remote level control VcA 

Remote location of the level control can be accomplished via the VCA control port. Connect the two leads from 
the optional remote volume control to these terminals. Set the system's maximum levels using the amplifier level 
controls and then use the remote VCA potentiometer as an attenuator from the maximum levels set.

 

WirinG the AAVcc-10K VcA Potentiometer

 – Atlas part number, AAVCC-10K, consists of a single 

gang "Decora" style wall plate with a pre-mounted 10K potentiometer and knob. Use two conductor unshielded wire 
connecting the plot terminals marked "VCA" on the back of the amp.

Summary of Contents for PA1001G

Page 1: ...ce Owner s Manual 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 PA1001G Power Amplifier Atlas Sound PA1001G 1 channel 100W 70V 100v commercial Power Amplifier Ul...

Page 2: ...y Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 TABLE OF CONTENTS Important Safety Instructions 3 Introduction Features and Applications 5 Front Panel Description 6 Rear Panel D...

Page 3: ...when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified s...

Page 4: ...tage on the product when connecting equipment Fire and or property damage may result Operate the product only with the voltage specified on the unit Fire and or electric shock may result if a higher v...

Page 5: ...mpact and engineered for reliability the Atlas Sound PA1001G will provide years of service and flexibility in today s conferencing background music and paging applications Key Features 100W x 1 70v 10...

Page 6: ...e Limit LED remains on recheck the load connections to the amp 4 Signal LED The Signal LED illuminates Green if there is audio signal present at the input of the amp 5 Input Gain The Left and Right ro...

Page 7: ...using the Left and Right RCA connectors These inputs are electrically summed into a mono signal 5 AC Fault LED This LED will illuminate Red if a fault has occured with the AC spike supression circuity...

Page 8: ...Out Jack and the Remote Level Control feature This switch determines if the Line Out signal is fixed Pre or works with the Remote Level Control Post The Down position is Pre Remote Level meaning the...

Page 9: ...as sensed audio signal and has triggered on it will take 15 20 min for it revert back into sleep mode even when there is no audio present Also the PA1001G level controls have no affect on this feature...

Page 10: ...excessive heat Ambient temperatures should not exceed 113 F 45 C when equipment is in use Video Pole Mount The PA1001G is ideally suited to be used in board or class room video audio applications The...

Page 11: ...cifications are subject to change without notice Owner s Manual PA1001G Power Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Pole Mount Pre Assembly Pol...

Page 12: ...KHz No Hi Pass Filter 3dB 100Hz 20KHz Hi Pass engaged Protection Circuits AC fuse T1 6A 250v 5mm x 20mm Thermal short circuit Signal to Noise Ratio 100dB below rated output A weighted Input Sensitivit...

Page 13: ...13 AtlasSound com Specifications are subject to change without notice Owner s Manual PA1001G Power Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 notes...

Page 14: ...AtlasSound com 14 Specifications are subject to change without notice Owner s Manual PA1001G Power Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 notes...

Page 15: ...15 AtlasSound com Specifications are subject to change without notice Owner s Manual PA1001G Power Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 notes...

Page 16: ...er the terms of this warranty All warranty returns must comply with our returns policy set forth below When products returned to Atlas Sound do not qualify for repair or replacement under our warranty...

Reviews: