Atlas PA1001G Owner'S Manual Download Page 4

 AtlasSound.com 

– 4 – 

Specifications are subject to change without notice.

Owner’s Manual

PA1001G Power Amplifier

1601 Jack McKay Blvd. • Ennis, Texas 75119  U.S.A.

Telephone: 800.876.3333 • Fax: 800.765.3435

 

When the deVice is in use

 

 

 

 
•  To prevent electric shock, do not remove the product cover as there are high voltage components inside.  
 

Refer all servicing to Atlas Sound. 

•  Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power  
 

cord from the AC outlet and contact Atlas Sound. Do not to attempt to continue operation with the product as this  

 

may cause fire or electric shock:

 

•  Smoke or strange smell coming from the unit.

 

•  If the product falls or the case is damaged.

 

•  If water or any metallic objects falls into the product.

 

•   If the power supply cord is damaged in any way.

 

•  If the unit is malfunctioning.

•  Do not insert or drop metallic objects or flammable materials into the ventilation holes of the product's cover, as this  
 

may result in electric shock or fire.

•  Do not place any containers with liquid or metallic objects on the top of the product. If any liquid spills into the unit,  
 

fire or electric shock may result.

•  Never operate this product or touch the power supply cord during an electrical storm, electric shock may result. 
•  Never exceed the wattage on the product when connecting equipment. Fire and/or property damage may result.
•  Operate the product only with the voltage specified on the unit. Fire and/or electric shock may result if a higher  
 

voltage is used. 

•  Do not modify, kink, or cut the power cord. Do not place the power cord in close proximity to heaters and do not place  
 

heavy objects on the power cord, including the product itself, doing so may result in fire or electrical shock. 

•  Replace the protective cover over the speaker terminals after installation. Do not touch the 70V speaker terminals as  
 

electric shock may result. 

•  Ensure that the safety ground terminal is connected to a proper ground. Never connect the ground to a gas pipe as a  
 

catastrophic disaster may result. 

•  Be sure the installation of the product is stable, avoid slanted surfaces as the product may fall and cause injury or  
 

property damage.

 

When installing the Product

 

 
•   Plugging in or unplugging the power cord with wet hands may result in electric shock. 
•  Never move the unit with the power cord plugged into the wall, as damage to the power cord may result.  
 

When unplugging the cord from the wall, grasp the plug, NOT the cord. 

•  Never install this product in humid or dusty locations, nor in direct sunlight, near sources of heat, or in areas where  
 

sooty smoke or steam are present. Fire and electric shock may result.

•  Keep all sides of the unit at least 3

1

2

" away from objects that may obstruct air flow to prevent the unit's internal  

 

temperature rise.

WArninG 

cAution 

Summary of Contents for PA1001G

Page 1: ...ce Owner s Manual 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 PA1001G Power Amplifier Atlas Sound PA1001G 1 channel 100W 70V 100v commercial Power Amplifier Ul...

Page 2: ...y Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 TABLE OF CONTENTS Important Safety Instructions 3 Introduction Features and Applications 5 Front Panel Description 6 Rear Panel D...

Page 3: ...when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified s...

Page 4: ...tage on the product when connecting equipment Fire and or property damage may result Operate the product only with the voltage specified on the unit Fire and or electric shock may result if a higher v...

Page 5: ...mpact and engineered for reliability the Atlas Sound PA1001G will provide years of service and flexibility in today s conferencing background music and paging applications Key Features 100W x 1 70v 10...

Page 6: ...e Limit LED remains on recheck the load connections to the amp 4 Signal LED The Signal LED illuminates Green if there is audio signal present at the input of the amp 5 Input Gain The Left and Right ro...

Page 7: ...using the Left and Right RCA connectors These inputs are electrically summed into a mono signal 5 AC Fault LED This LED will illuminate Red if a fault has occured with the AC spike supression circuity...

Page 8: ...Out Jack and the Remote Level Control feature This switch determines if the Line Out signal is fixed Pre or works with the Remote Level Control Post The Down position is Pre Remote Level meaning the...

Page 9: ...as sensed audio signal and has triggered on it will take 15 20 min for it revert back into sleep mode even when there is no audio present Also the PA1001G level controls have no affect on this feature...

Page 10: ...excessive heat Ambient temperatures should not exceed 113 F 45 C when equipment is in use Video Pole Mount The PA1001G is ideally suited to be used in board or class room video audio applications The...

Page 11: ...cifications are subject to change without notice Owner s Manual PA1001G Power Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Pole Mount Pre Assembly Pol...

Page 12: ...KHz No Hi Pass Filter 3dB 100Hz 20KHz Hi Pass engaged Protection Circuits AC fuse T1 6A 250v 5mm x 20mm Thermal short circuit Signal to Noise Ratio 100dB below rated output A weighted Input Sensitivit...

Page 13: ...13 AtlasSound com Specifications are subject to change without notice Owner s Manual PA1001G Power Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 notes...

Page 14: ...AtlasSound com 14 Specifications are subject to change without notice Owner s Manual PA1001G Power Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 notes...

Page 15: ...15 AtlasSound com Specifications are subject to change without notice Owner s Manual PA1001G Power Amplifier 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 notes...

Page 16: ...er the terms of this warranty All warranty returns must comply with our returns policy set forth below When products returned to Atlas Sound do not qualify for repair or replacement under our warranty...

Reviews: