2 0 |
P a g e
Atlas UV Standard Output System Specifications
ATLAS UV EQUIPMENT SPECIFICATIONS
Residential systems (standard output lamps)
MODEL
L12
L22
L41
L57
L79
Flow Rate
(@30mJ/cm
2
)
11.4 lpm
22.7 lpm
41 lpm
57 lpm
79 lpm
0.7 m
3
/hr
1.4 m
3
/hr
2.5 m
3
/hr
3.4 m
3
/hr
4.8 m
3
/hr
Flow Rate
(@40mJ/cm
2
)
9.1 lpm
17 lpm
31 lpm
45.4 lpm
59 lpm
0.5 m
3
/hr
1.0 m
3
/hr
1.9 m
3
/hr
2.7 m
3
/hr
3.6 m
3
/hr
Port Size
½”MNPT
¾”MNPT
¾”MNPT
1”MNPT
1”MNPT
Electrical
90-265V/50-60Hz.
Plug Type
European, CEE 7/7
Lamp Power (Watts)
15
22
39
50
42
Power (Watts)
20
30
49
62
51
Replacement Lamp
RL-12
RL-22
RL-41
RL-57
RL-79
Replacement Sleeve
RQ-12
RQ-22
RQ-41
RQ-57
RQ-79
Reactor
Dimensions
6.4 x 36.4 cm
(2.5 x 14.3”)
6.4 x 54.2 cm
(2.5 x 21.3”)
6.4 x 89.5 cm
(2.5 x 35.2”)
6.4 x 101.6 cm
(2.5 x 40.0”)
8.9 x 91.7 cm
(3.5 x 36.1”)
Chamber
Material
304 Stainless Steel, A249 Pressure Rated Tubing
Controller
Dimensions
17.2 x 9.2 x 7.6 cm (6.8 x 3.6 x 3”)
Operating
Pressure
0.7-10.3 bar (10-150 psi)
Operating Water
Temperature
2-40° C (36-104° F)
UV Monitor Port
No
Yes (optional UV sensor module sold separately)
Solenoid Output
Yes (optional solenoid module sold separately)
Dry Contacts
Yes (remote alarm module sold separately)
4-20mA Output
Yes (4-20mA module sold separately)
Lamp Change Reminder
(audible & visual)
Yes
Lamp Out Indicator
(audible & visual)
Yes
Shipping Weight
3.3 kg
(7.3 lbs)
4.2 kg
(9.3 lbs)
6.8 kg
(15.0 lbs)
8.0 kg
(17.6 lbs)
7.5 kg
(16.5 lbs)