1 6 |
P a g e
Operational Screens with UV Monitor Upgrade
On systems that have the UV sensor installed, the default screen shows the
UV Intensity
. At any
point during operation the user is able to scroll through the
UV Intensity
,
Lamp life remaining
and
QR Code
screens by pressing the button located on the front of the controller.
UV Intensity (with UV Monitor Upgrade)
The UV Intensity screens display the level of UV light detected by the sensor. UV intensity can be
affected by poor water quality, scaling on the quartz sleeve and/or sensor, lamp failure or lamp
expiring. The following screens show the UV Intensity dropping.
Below 56%, the numbers and warning sign turn red and an audible chirp is given by the ballast
every 15 seconds. Below 51%, the screen is solid red and a constant audible alarm is given. This
alternates with a screen indicating “water may be unsafe for consumption”. With the solenoid
module, the controller de-activates the solenoid valve, shutting off all water flow.