– 11 – AtlasSound.com
Specifications are subject to change without notice.
Owner’s Manual
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
ECS-204
20A Power Conditioner & Sequencer
Rear Panel Features
7.
Switch Configuration Settings
– There are 5 Dip Switches that control Sequence Delay Timing, System link combining of 2 or 3
ECS-204 units together and the EVS Reset mode. Follow the chart in the manual or the chart located on the top cover of the unit
for operation settings. Zero (0) indicates the “UP” position and One (1) indicates the “DOWN” position.
Note:
After changing a Dip
Switch setting, the unit power must be reset for the changed setting to take effect.
A.
Sequence Delay Settings
– The ECS-204 has four timing settings between each sequence. Follow the chart for the settings
for Switches 1 & 2. When daisy chaining multiple units together each unit’s settings only relate to that individual unit.
Therefore, each unit can be different or all can have the same setting. Follow the chart in the manual or the chart located on
the top cover of the unit for operation settings.
Note:
After changing a Dip Switch setting, the unit power must be reset for the
changed setting to take effect.
B.
System Link Settings Master or Slave Unit
– Determine if you daisy chaining two or three units together. Choose the
position of the sequence in perspective to the equipment you are activating. The first unit will be known as the Master Unit, all
others are Slave Units. Switches 3 & 4 determine the position of the unit and sequence timing. Follow the chart for the settings
for Switches 3 & 4. When a unit is selected as a Slave Unit the Front Panel Slave Mode LED will illuminate. Also follow the
System Control Port section below for unit daisy chain connection.
Note:
After changing a Dip Switch setting, the unit power
must be reset for the changed setting to take effect.
C.
Extreme Voltage Shutdown (EVS) Settings
– There are two settings to meet your install requirements. Dip Switch 5 assigns
the ECS-204 to be in EVS Auto Reset or Manual Reset mode.
Note:
After changing a Dip Switch setting, the unit power
must be reset for the changed setting to take effect.
•
Auto Reset
– Place Dip Switch 5 in the UP (0) position. When set to Auto Reset the EVS circuit will shut Off Sequence
1-4. The AC Outlets will auto reset back on when the AC Mains voltage has stabilized between 107V and 128V.
Note:
After changing a Dip Switch setting, the unit power must be reset for the changed setting to take effect.
•
Manual Reset
– Place Dip Switch 5 in the Down (1) position. When set to Manual Reset the EVS circuit will shut Off
Sequence 1-4. The AC Outlets will not turn back on until back on until the AC Mains voltage has stabilized between
107V and 128V and a new sequence has been manually activated.
Note:
After changing a Dip Switch setting, the unit
power must be reset for the changed setting to take effect.
+12V GND
RMT V IN
5-24V DC
GND MM
SW
+12VDC
AC Mains Voltage
USB
Charge & Light Port
5V DC 1A
*May Not Charge All Devices
Power
Unswitched Outlets 120V 60Hz 16A 1920W
20A Circuit
Breaker
Push to Reset
ECS-204
20A Power Conditioner
& Sequencer
120V AC 60Hz
20A Max 2400W
Lamp
On
Off
120V 16A 1920W
Continuously
120V 16A 1920W
Continuously
Filtered Outlets 120V 60Hz 15A 1800W Continuously
Filtered Outlets 120V 60Hz 15A 1800W Continuously
Unswitched
Outlet
Sequence 3
Unfiltered High Current
Sequence 2
Sequence 1
Remote Activation
EPD
Emergency
Power Down
SEQ 4 Output
Link Out
to 2nd ECS-204
(Not Ethernet)
0
1
1
SW
2 3 4 5
1601 Jack McKay Blvd. • Ennis, TX 75119
800.876.3333 • AtlasSound.com
Note:
See Top Cover
for Settings
Caution:
All AC Outlets Combined Not To Exceed 16A 1920W Continuously
Remote Activation Wiring Chart
Using Momentary Type Switch
Remote Momentary Switch
Note:
Parallel to Front Panel Activation Switch.
GND
MM
SW
Using Latching (CC) Contact Closure
Remote Latching (CC) Contact Closure Switch
Note:
Overrides Front Panel Activation Switch.
+12VDC
RMT
V IN
Using DCV
+
–
From External DC Source
Note:
Overrides Front Panel Activation Switch.
GND
RMT V IN
5-24V
EPD
Emergency Power Down
Remote Latching (CC) Contact Closure Switch
Note: When Control Port Pins are Shorted,
All Outputs Turn Off Together.
Release and Start a New Sequence.
System Configuration Switch Settings
Sequence Delay SW 1,2
00
6 Sec
3 Sec
3 Sec
3 Sec
01
15 Sec
6 Sec
6 Sec
6 Sec
10
1 Min
9 Sec
9 Sec
9 Sec
11
2 Min
15 Sec
15 Sec
15 Sec
Seq 1
Seq 2
Seq 3
Seq 4
System Link
Master
0
0
Slave 1
1
0
Slave 2
1
1
SW 3
SW 4
SW 5
SW 5
0
1
EVS (Extreme Voltage Shutdown)
Auto Reset
Manual Reset
0
1
1
SW
2 3 4 5
System Link In
Slave Mode from 2nd ECS-204
Detailed Product Information
CONFORMS TO
ANSI/UL STD 60065
CERTIFIED TO
CAN/CSA STD
C22.2 NO. 60065
4 0 0 4 8 6 2
(Front)
(Back)
ECS-204 - Silk Screen
ATS003972 RevD 11/12
2 Color: White, PMS 293 U