Safety Instructions

1.   Read these instructions.
2.   Keep these instructions.
3.   Heed all warnings.
4.   Follow all instructions.
5.   Do not use this apparatus near water.
6.   Clean only with dry cloth.
7.   Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8.   Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce 

heat. 

9.   Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the 

other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your 
safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 

10.  Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they 

exit from the apparatus.

11.  Only use attachments/accessories specified by the manufacturer.
12.  Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is 

used use caution when moving the cart/apparatus combination to avoid injury from tip-over.  

13.  Unplug this apparatus during lightning storms or when unused for long periods of time. 
14.   Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as 

power-supply cord or plug is damaged, liquid has been spilled, or objects have fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, or has been dropped. 

15.  

WARNING:

 To reduce the risk of fire or electric shock, this apparatus should not be exposed to rain or moisture and objects filled 

with liquids, such as a vase, should not be placed on this apparatus. 

16.  To completely disconnect this equipment from the mains, disconnect the power supply cord plug from the receptacle. 
17.  The mains plug of the power supply cord shall remain readily operable. 

PA Amplifier 

Model AA35 

Output Rated 35W 

Designed and Engineered  

by Atlas Sound 

Made In CHINA 

RISK OF ELECTRIC SHOCK 

DO NOT OPEN

ATTENTION

 RISQUE DE DECHARGE ELECTRIQUE

-NE PAS OUVRIR.

WARNING

 

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK

 DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.

CAUTION

´

The lightning flash with arrowhead symbol within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated “dangerous voltage “ within the 
product’s enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons. 

The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the 
literature accompanying the product.  

Summary of Contents for AP-C15D

Page 1: ...765 3435 AP C15D Power Conditioner Unswitched Outlets 120V 10A Circuit Breaker Power Power On Wiring Fault Breaker Open AC Fault Abnormal Voltage AC Mains Voltage AP C15D Power Conditioner Off Low High 15A 1601 JackMcKay Blvd Ennis TX 75119 www atlassound com On Off Lamp Filtered Outlets 120V 60Hz 10A MAX 1200W High Current 120V 10A Unfiltered Unswitched 120V 10A AC 120V 60Hz 1440W 12A ...

Page 2: ...r Conditioner 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Table of Contents Safety Instructions 3 Introduction 5 Key Features 6 Applications 6 Front Panel Features 6 Rear Panel Features 8 Installation 8 Troubleshooting Guide 9 Specifications 10 Warranty 12 ...

Page 3: ...e cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has ...

Page 4: ... holes of the product s cover as this may result in electric shock or fire Do not place any containers with liquid or metallic objects on the top of the product If any liquid spills into the unit fire or electric shock may result Never operate this product or touch the power supply cord during an electrical storm electric shock may result Never exceed the wattage on the product when connecting equ...

Page 5: ...l problem the AP C15D features Dual Clamping Suppression technology DCS If a spike intrudes the AC system the AP C15D incoming AC Mains has special suppression circuitry to eliminate the unwanted energy and in the unlike ly event of any energy getting pass the first stage each output section has redundant DCS circuitry clamping the unwanted energy This circuitry is very fast and can suppress unwan...

Page 6: ...hose inconveniences The following are just a few examples of applications the AP C15D can be used Restaurants Houses of Worship Schools Home Theaters Office Buildings Sports Bars Front Panel Features 1 Unswitched AC Outlet The two 120VAC outlets are always live when the AP C15D power cord is plugged into an AC mains power source and voltage is present If voltage is present at the outlets it will b...

Page 7: ...d into the AP C15D High AC Line Mains The Abnormal Voltage LED will flash between 128VAC 132VAC indicating possible damage may occur to equipment due to high AC Mains voltage The AP C15D outlets will remain active but the LED will stay flashing even if the voltage returns to a normal operating range To stop the LED from flashing the Power switch must be cycled Off Note It is recommend ed prior to ...

Page 8: ...on the AC Mains Meter Note The AC mains power switch does not affect the Unswitched AC Outlets The Unswitched Outlets are protected by the surge protection circuitry but will not be shut off by the EVS circuit 5 XLR Light Socket A 12VDC XLR light socket provides power for the optional ECS GNL light 6 Light Socket Power Switch This switch turns the XLR light socket ON OFF Installation Before instal...

Page 9: ...ent that was connected to that AC Mains Line to be inspected for proper operation If the problem persists contact your local power company for the cause of unstable AC line conditions Issue Abnormal LED Flashing and you have power to all outlets Possible Cause The AC Mains Voltage exceeded 128VAC or the voltage dropped below 107VAC Action Needed The AP C15D must be reset to turn off the LED Measur...

Page 10: ...o position On Off AC Mains Power Cord 9 3m 14 gauge Technical Data Current Rating 15 amps Operating Voltage 102VAC 132VAC High Voltage Surge Protection Trigger at 133VAC 1ms typically Low Voltage Protection Trigger 101VAC 1ms typically Voltmeter Accuracy 1 5VAC Spike Protection Modes DCS Dual Clamping Suppression Circuitry on Incoming AC Mains and Each Section Output Min Spike Clamping Voltage 460...

Page 11: ... 11 AtlasSound com Specifications are subject to change without notice Owner s Manual AP C15D Power Conditioner 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 876 3333 Fax 800 765 3435 Notes ...

Page 12: ...inal sales invoice should be retained as evidence of purchase under the terms of this warranty All warranty returns must comply with our returns policy set forth below When products returned to Atlas Sound do not qualify for repair or replace ment under our warranty repairs may be performed at prevailing costs for material and labor unless there is included with the returned product s a written re...