background image

Page 17

Strategy Series – Fire-Resistant System Components**

Standard Series – Fire-Resistant System Components***

*  Enclosure-Fiber kit, speaker assembly, and baffle are ordered separately 

and must be used together to comply with UL classification.

**

Fire-Resistant systems using Strategy 
Series will be available 3rd Quarter 1999.

*  Enclosure-Fiber kit and speaker assembly are ordered separately

ENCL0SURE-

MOUNTS

INCLUDES

MOUNTS CHOICE

FIBER KIT*

SPEAKER ASSEMBLY*

SPEAKER

XFMR

OF BAFFLE*

FA95-4FR

FA114T72FR

FA114

T72

FA51-4FR

FA134T42FR

T42

FA170-4FR

FA97-4FR

FA134T47FR

FA134

T47

FA720-4FR

FA134T87FR

T87

FA730-4FR

FA95-6FR

FA116T72FR

FA116

T72

FA51-6FR

FA136T42FR

T42

FA170-6FR

FA97-6FR

FA136T47FR

FA136

T47

FA720-6FR

FA136T87FR

T87

FA730-6FR

ENCL0SURE-

SPEAKER

INCLUDES

FIBER KIT*

ASSEMBLY*

SPEAKER

XFMR

MOUNTS CHOICE OF BAFFLE*

95-8FR

C5AT25FR

T25

51-8FR

(mounts 95-8FR & 96-8FR)

96-8FR

C5AT70FR

T70

62-8FR

(mounts 95-8FR & 96-8FR)

191-78FR

C5AT72FR

C5A

T72

61-8WFR

(mounts 95-8FR & 96-8FR)

193-8FR

C5AT42FR

T42

164-8FR

(mounts 191-78FR)

198-8FR

C5AT47FR

T47

169-8FR

(mounts 193-8FR)

C5AT87FR

T87

161-8FR

(mounts 198-8FR)

95-8FR

C10AT25FR

T25

51-8FR

(mounts 95-8FR & 96-8FR)

96-8FR

C10AT70FR

T70

62-8FR

(mounts 95-8FR & 96-8FR)

191-78FR

C10AT72FR

C10A

T72

61-8WFR

(mounts 95-8FR & 96-8FR)

193-8FR

C10AT42FR

T42

164-8FR

(mounts 191-78FR)

198-8FR

C10AT47FR

T47

169-8FR

(mounts 193-8FR)

C10AT87FR

T87

161-8FR

(mounts 198-8FR)

95-8FR

C803AT25FR

T25

51-8FR

(mounts 95-8FR & 96-8FR)

96-8FR

C803AT70FR

T70

62-8FR

(mounts 95-8FR & 96-8FR)

191-78FR

C803AT72FR

C803A

T72

61-8WFR

(mounts 95-8FR & 96-8FR)

193-8FR

C803AT42FR

T42

164-8FR

(mounts 191-78FR)

198-8FR

C803AT47FR

T47

169-8FR

(mounts 193-8FR)

C803AT87FR

T87

161-8FR

(mounts 198-8FR)

ENCL0SURE-

MOUNTS

SPEAKER ASSEMBLY INCLUDES

FIBER KIT*

SPEAKER ASSEMBLY*

SPEAKER

XFMR

BAFFLE

FA95-8FR

FA118T72-170FR

T72

FA170-8

FA118T72-51FR

FA118

T72

FA51-8

FA118T72-720FR

T72

FA720-8

FA118T72-730FR

T72

FA730-8

FA95-8FR

FA138T42-51FR

T42

FA51-8

FA138T42-720FR

T42

FA720-8

FA138T42-730FR

FA138

T42

FA730-8

FA138T47-51FR

T47

FA51-8

FA138T47-720FR

T47

FA720-8

FA138T47-730FR

T47

FA730-8

FA138T87-51FR

T87

FA51-8

FA138T87-720FR

T87

FA720-8

*  Enclosure-Fiber kit, speaker assembly, and baffle are ordered separately 

and must be used together to comply with UL classification.

*  Enclosure-Fiber kit, speaker assembly, and baffle are ordered separately 

and must be used together to comply with UL classification.

ENCL0SURE-

SPEAKER

SPEAKER ASSEMBLY INCLUDES

MOUNTS CHOICE

FIBER KIT*

ASSEMBLY*

SPEAKER

XFMR

OF BAFFLE*

FC104T25FR

T25

51-4FR

96-4FR

FC104T70FR

T70

(Mounts 96-4FR)

or

FC104T42FR

FC104

T42

161-4FR

198-4FR

FC104T47FR

T47

(Mounts 96-4FR)

FC104T72FR

T72

***

Fire-Resistant systems using Standard 
Series will be available 2nd Quarter 1999.

Summary of Contents for 191-78FR

Page 1: ...Selling Specifying Installing Atlas Soundolier FR Series UL Classified Fire Resistant Speaker Assemblies UL C LASSIFIE D R...

Page 2: ...ational Conference of Building Officials ICBO UBC Standard American National Standards Institute ANSI American Society for Testing and Materials ASTM Local Authorities Standards Testing Regulatory Ins...

Page 3: ...egrity A metal can loudspeaker system seals the opening but cannot maintain the ceiling s fire resistance properties because the metal readily conducts the heat of the fire into the space above the ce...

Page 4: ...standards Specify with confidence Consultants and architects can specify the FR Series with confidence knowing they meet Atlas Soundolier s high general perfor mance and quality standards Architects a...

Page 5: ...s dealers and customers will recognize many components of the FR Series For example a typical FR Series Fire Resistant Speaker Assembly would consist of a model 96 4FR FR Enclosure Fiber Kit with 96 4...

Page 6: ...a building Specifying the FR Series It s easy to specify the FR Series Fire Resistant Speaker Assemblies Just choose a conventional Atlas Soundolier model that fills the performance and aesthetic nee...

Page 7: ...n local standards While these standards are usually based on recognized national and international standards they vary from locality to locality Standards Regulatory and Testing Organizations Finally...

Page 8: ...F International ISO and IEC UL Standards and Testing Con t The FR Series Fire Resistant Speaker Assemblies are UL Classified under UL Standard 263 Fire Tests of Building Construction and Materials for...

Page 9: ...nal Conference of Building Officials ICBO UBC Standard The International Conference of Building Officials is a non profit service organization owned and controlled by its member cities counties and st...

Page 10: ...lding codes and other regulations Most use all or substantial portions of national codes such as the NEC and UBC Certain non governmental organizations such as insurance companies also influence both...

Page 11: ...Insurance Companies 3 Install the FR Series Fire Resistant Speaker Assemblies Properly Follow the FR Series installation instructions carefully Terminology Fire Resistance UL and other authorities use...

Page 12: ...floor or roof above Plenums may be used to supply or exhaust air from the room below if materials in the plenum are non combustible or of limited combustibility and plenum rated The primary concern f...

Page 13: ...al customers The ultimate user is usually a business or governmental agency or a building owner management company or leasee in any situation where building codes require a fire resistant ceiling syst...

Page 14: ...ce and aesthetic options The Technical Buyer The technical buyer is any person or agency that writes or enforces technical specifications for the product or project This includes local regulatory agen...

Page 15: ...es and will help speed the process of local approval The Coach It is also possible that a competitor s product may be UL Listed for Fire Protective Signaling or General Signaling under UL Standard 148...

Page 16: ...aker systems by constructing and installing fire resistant rear enclosures from drywall While these drywall boxes can meet local codes they are costly to build cumbersome to install and the added weig...

Page 17: ...so consult with the electrical contractor HVAC contractor and any other contractors who may be working in the ceiling to make sure the loudspeaker system can be installed with no conflicts 3 Install t...

Page 18: ...ation for fire resistance enclosure fiber kits must be used with FR Series components Easy to Order See next page Choose from 43 FR Series speaker assemblies Select matching FR enclosure fiber kit Sel...