5. 2-Gang Low Voltage Retro-Fit Ring
Where Class 2 low voltage wiring is acceptable and cut-in retro-fit install is required, most
low voltage rings will work. Figure 9 is an Arlington LV2.
Installing the 24VDC Power Supply
Powering the WTSD BUS requires use of the included external power supply. A UL
Certified external 24VDC 1A power supply is supplied to power the WTSD-MIX31K. It is
suggested to place the WTSD within 10ft of a 120V AC outlet. If this is not possible, the
power supply wire for the 24VDC output can be extended up to 50ft.
Note:
This does not
void the warranty as it is the low voltage wire that is being extended. Pay attention to the
DCV polarity when reconnecting the removable Phoenix connector. Only use the included
approved power supply or failure may occur. Must be installed by a qualified technician.
Local electrical codes will apply.
Installing the WTSD Indoors
It is recommended before installing the WTSD to review the local codes for placement
of the device. Installing a WTSD does not require using the WTSD-COVER but it is
recommended to use the WTSD-COVER for security reasons. Refer to the WTSD-COVER
section for more details. For most indoor applications, a low voltage electrical ring is all
that is required to mount the WTSD. Using an electrical ring with a WTSD allows for an
easy spacious installation.
Installing the WTSD Outdoors
If using a WTSD outdoors, it is recommended to use the optional stainless-steel locking
WTSD-COVER. The WTSD needs to be mounted in a location that is under a building
overhang or a under weather deflection shield.
Note:
Do not place directly in rain or snow.
Using a quality outdoor electrical box is critical to obtaining a weather sealed fit.
Figure 9