Suspended Installation via Down Pipe (Not-Included) Using 

3

/

4

" Diameter Ceiling Fan Hardware

The AtlasIED DA-PM8GD may also be installed using industry standard ceiling fan hardware. This hardware is available at most local hardware stores. 
Using this type of installation allows Ethernet cable and safety cable to be concealed with the down pipe providing a very clean installation.

1.  Rotate the top cover counterclockwise and pull up to remove. (Figures 1 and 2)

2.  Locate suitable support structure in the area the speaker is to be installed.

3.  Mount the ceiling mount canopy and down pipe per manufacturer instructions.

4.  Screw the DA-PM8GD top cover onto the bottom of the down pipe, install the safety screw though the side of the top cover and through the end    
 

of the down pipe. (Figure 9)

5.  Route the bare end of the safety cable though the included clamp, then around a suitable support structure, and back through the clamp.  
 

(Figures 3 and 4)

6.  Route the eyelet end of the safety cable down through pipe and the cover of the DA-PM8GD. Attach the eyelet to one of the outer mounting holes  
 

on the support plate of the DA-PM8GD using the included mounting screw. (Figure 9)

7.  Route the Ethernet cable through the down pipe and connect to the RJ45 Connector.

8.  Position the speaker under the top cover, align the side cover screws and rotate the speaker clockwise to align the top cover mounting screw  

 

 

holes. Install the 3 mounting screws which are located in the hardware bag. Then tighten the side cover screws. (Figure 9)

Wiring the DA-PM8GD Dante PoE Speaker

The DA-PM8GD ships configured for single speaker use. It can also be configured to drive a second passive version speaker of the same type PM8GD. 
The DA-PM8GD ships in 1 Channel Mode, the amplifier will deliver 15W power when connected to a PoE+ Ethernet switch and 10W when connected 
to PoE. The DA-PM8GD secondary speaker output terminal is disabled until the amplifier operational mode settings are changed during system set-up 
from 1 Channel to 2 Channel Mode. Operational Mode selection are configured in the AtlasIED Discovery and Control Software. Refer to the section 
AtlasIED Discovery and Control Software for Operation Mode Settings. 

Electrical wiring requires a single Cat 5e/6 cable to be run from the PoE Ethernet Switch to the DA-PM8GD. Industry wiring standards for 802.3af and 
802.3at PoE has a distance limit of 100 meters or 328ft, which is also the limit for the data transmission for Ethernet cables.

When installing a DA-PM8GD, the speaker comes preconfigured out the box in Single Speaker Mode. The only electrical cable connecting to the 
DA-PM8GD is a CAT 5e/6. 

421.13

16.58

316.59

12.46

A

A

SECTION A-A

Figure 9

Summary of Contents for DA-PM8GD

Page 1: ...inate created Dante is an uncompressed multi channel digital media networking technology with near zero latency and synchronization Hundreds of Dante enabled products are available from many manufactu...

Page 2: ...ore times the weight of the DA PM8GD The hardware employed must be safely and securely attached both to the speaker and the structure in question using only the mounting holes A general rule for soft...

Page 3: ...xtra cable length for a service loop during assembly Note There will be no audio present at these secondary speaker terminals until the amp is configured from Single channel mode to Dual channel mode...

Page 4: ...d All other Trademarks are property of their respective owners No endorsement is implied Due to continual product development specifications are subject to change without notice ATS006960 RevC 6 22 At...

Page 5: ...ty cable down through pipe and the cover of the DA PM8GD Attach the eyelet to one of the outer mounting holes on the support plate of the DA PM8GD using the included mounting screw Figure 9 7 Route th...

Page 6: ...llation and safety instructions when hanging a DA PM8GD It is important not to twist the CAT 5e 6 cable during installation or damage to the wire or RJ45 may occur Wiring the DA PM8GD to a PM8GD Conne...

Page 7: ...ve owners No endorsement is implied Due to continual product development specifications are subject to change without notice ATS006960 RevC 6 22 AtlasIED com TELEPHONE 800 876 3333 SUPPORT ATLASIED CO...

Page 8: ...needed to handle network traffic There are three things to look for at a minimum or system dropouts may occur Refer to Audinate for products they recommend Gigabit speed Network switch it must be a ma...

Page 9: ...strial Paper Sensitivity 1W 1m 96dB Average Amplification Type Two Channel Class D Topology Power Input PoE IEEE 802 3af PoE IEEE 802 3at Single Ch Mode Power Rating RMS PoE IEEEE 802 3AF 10 Watts Max...

Page 10: ...l wattage figures are calculated using the rated nominal impedance 3 Frequency response and sensitivity are half space measurements Network Ethernet IEEE 802 3 10 100Base T PoE PoE IEEE 802 3 AF AT Co...

Page 11: ...abor unless there is included with the returned product s a written request for an estimate of repair costs before any nonwarranty work is performed In the event of replacement or upon completion of r...

Reviews: