Procedure
Starting from the Main screen (see
):
• Press the key “Menu” (F1).
• Press the arrow down key (1) until “Service” is followed by a horizontal arrow.
• Activate the menu by pressing tabulator key (2).
• A screen similar to the one below appears:
“Service Timer”
“Running Hours”
7971 “hrs”
“Menu”
“Reset”
F1
F2
F3
• The screen shows that the total compressor running time is 7971 hours.
• Press the tabulator key (2), following screen appears:
“Next Timer”
“Level”
A B
8000 “hrs”
“Back”
“Reset”
F1
F2
F3
• The screen shows that the next service plans to be carried out are plans A and B and that these plans are
to be carried out every 8000 running hours.
• Press the arrow down key (1) to find out which service plans were carried out previously, following screen
appears:
“Previous Timer”
“Level”
A
4008 “hrs”
“Back”
F1
F2
F3
• The screen shows that plan A was carried out at 4008 running hours.
• Stop the compressor, switch off the voltage and carry out the service operations related to the indicated
service plans, see section
Preventive maintenance schedule.
• Switch on the voltage and scroll to the “Next Timer” service screen.
• Press the “Reset” button (F3). Confirm the question for resetting.
The “Reset” button only appears when the “Next Timer” level is almost reached.
After pressing the arrow down key in the “Service Timer” screen, the “Life Time” hours are
shown, i.e. the number of hours elapsed since initial programming ex-factory. This timer is
not taken into account.
Instruction book
48
APFS998935v00
Summary of Contents for ZT-55
Page 1: ...CustomDesign Oil free Air Project 998935 Customer AIR SEP USA ZT 55 Instruction book ...
Page 2: ......
Page 13: ...General view Rear view Instruction book APFS998935v00 11 ...
Page 25: ...Typical example Drive motor M1 Instruction book APFS998935v00 23 ...
Page 57: ...4 2 Installation proposals Installation proposal ZT Pack Instruction book APFS998935v00 55 ...
Page 88: ......
Page 89: ......