7.4.4 Specific data of ZT30 up to ZT45
Unit
ZT30-7.5
ZT30-8.6
ZT37-7.5
ZT37-8.6
ZT45-7.5
ZT45-8.6
Nominal
working
pressure
bar(e)
7 8 7 8 7 8
Maximum
working
pressure
bar(e)
7.5 8.6 7.5 8.6 7.5 8.6
Maximum
working
pressure, Full-
Feature
bar(e)
7.25 8.35 7.25 8.35 7.25 8.35
Minimum
working
pressure
bar(e)
4.0 4.0 4.0 4.0 4.0 4.0
Installed motor
power
kW
30 30 37 37 45 45
Oil
capacity
l
25 25 25 25 25 25
Sound
pressure level
1)
dB(A)
69 69 71 71 73 73
Sound
pressure level,
WorkPlace Air
System
1)
dB(A)
66 66 68 68 70 70
7.4.5 Specific data of ZR30 up to ZR45
Unit ZR30-7.5
ZR30-8.6 ZR37-7.5 ZR37-8.6
ZR45-7.5 ZR45-8.6
Nominal
working
pressure
bar(e) 7 8 7 8 7 8
Maximum
working
pressure
bar(e) 7.5 8.6 7.5 8.6 7.5 8.6
Maximum
working
pressure, Full-
Feature
bar(e) 7.25 8.35 7.25 8.35 7.25 8.35
Minimum
working
pressure
bar(e) 4.0 4.0 4.0 4.0 4.0 4.0
Installed motor
power
kW
30 30 37 37 45 45
Oil
capacity
l
25 25 25 25 25 25
Cooling water
consumption
at temperature
rise of 15°C
l/s 0.55
0.55 0.7
0.7
0.83 0.83
Sound
pressure level
1)
dB(A)
66 66 68 68 70 70