- 57 -
LIMITATIONS
1)
Compressor:
PAROIL S i.s.o. PAROIL M
PAROIL 5W40 i.s.o. 15W40
Designation
XA(S) 137 DD -
XA(S) 300 DD7
XA(S) 137 DDG -
XA(S) 300 DD7G
XAHS 107 DD -
XAHS 250 DD7
230/400 V (3 phase)
Minimum effective receiver pressure
bar(e)
4
4
4
psi
58
58
58
Maximum effective receiver pressure, compressor
unloaded
bar(e)
8.5
8.5
13.5
psi
123
123
196
Maximum ambient temperature at
sealevel EC
standard
°C
48
48
49
°F
118
118
120
aftercooler
option
°C
40
40
41
°F
104
104
106
Maximum ambient temperature at
sealevel NON EC
standard
°C
53
53
53
°F
127
127
127
aftercooler
option
°C
45
45
45
°F
113
113
113
Minimum starting temperature
°C
- 10
- 10
- 10
°F
14
14
14
Minimum starting temperature, with coldstart equipment
1)
°C
- 20
- 20
- 20
°F
- 4
- 4
- 4
Altitude capability
see curves