- 41 -
ACTIVATING A DRY-CHARGED BATTERY
•
Take out the battery.
•
Battery and electrolyte must be at equal
temperature above 10°C (50°F).
•
Remove cover and/or plug from each cell.
•
Fill each cell with electrolyte until the level
reaches 10 mm (0.4 in) to 15 mm (0.6 in) above
the plates, or to the level marked on the battery.
•
Rock the battery a few times so that possible air
bubbles can escape; wait 10 minutes and check the
level in each cell once more; if required, add
electrolyte.
•
Refit plugs and/or cover.
•
Place the battery in the compressor.
RECHARGING A BATTERY
Before and after charging a battery, always check the
electrolyte level in each cell; if required, top up with
distilled water only. When charging batteries, each
cell must be open, i.e. plugs and/or cover removed.
Apply with preference the slow charging method and
adjust the charge current according to the following
rule of thumb:
battery capacity in Ah divided by 20 gives safe
charging current in Amp.
BATTERY MAINTENANCE
•
Keep the battery clean and dry.
•
Keep the electrolyte level at 10 mm (0.4 in) to
15 mm (0.6 in) above the plates or at the indicated
level; top up with distilled water only.
•
Keep the terminals and clamps tight, clean, and
lightely covered with petroleum jelly.
STORAGE
Run the compressor regularly, e.g. twice a week, until
warm.
Load and unload the compressor a few times to
operate the unloading and regulating components.
Close the air outlet valves after stopping.
SERVICE PAKS
A Service Pak is a collection of parts to be used for a
specific maintenance measure.
It guarantees that all necessary parts are replaced at
the same time keeping down time to a minimum.
The order number of the Service Paks are listed in the
Atlas Copco Parts List.
SERVICE KITS
A service kit is a collection of parts to fit a specific
repair or rebuilding task.
It guarantees that all necessary parts are replaced at
the same time which improves the uptime of the unit.
The order numbers of the Service Kits are listed in the
Atlas Copco Parts List.
COMPRESSOR ELEMENT OVERHAUL
When a compressor element is due for overhaul, it is
recommended to have it done by Atlas Copco. This
guarantees the use of genuine parts and correct tools
with care and precision.
LIABILITY
The manufacturer does not accept any liability for any
damage arising from the use of non-original parts and
for modifications, additions or conversions made
without the manufacturer’s approval in writing.
Use a commercial automatic battery
charger according to its manufacturer’s
instructions.
If the compressor is going to be stored
without running from time to time,
protective measures must be taken.
Contact Atlas Copco.