- 67 -
PERFORMANCE DATA
At reference conditions, if applicable, and at normal shaft speed, unless otherwise stated.
1)
Free Air Delivery (volume flow rate) is measured according to ISO 1217 ed.3 1996 annex D
Tolerance:
•
+/- 5% 25 l/s (53 cfm) < FAD < 250 l/s (530 cfm)
•
+/- 4% 250 l/s (530 cfm) < FAD
The international standard ISO 1217 corresponds to following national standards:
•
British BSI 1571 part 1
•
German DIN 1945 Part 1
•
Swedish SS-ISO 1217
•
American ANSI PTC9
Designation
XAHS 146 Dd
XAHS 300 DD6
XATS 156 Dd
XATS 350 DD6
XA(S) 186 Dd
XA(S) 375 DD6
XAVS 166 Dd
XAVS 340 DD6
XAHS 186 Dd
XAHS 375 DD6
XATS 156 Dd
XATS 350 DD6
XA(S) 186 Dd
XA(S) 375 DD6
COM3
COM3
COM3
COM3
COM3
COM2
COM2
Engine shaft speed, normal and maximum
r/min
2300
2300
2300
2200
2200
2300
2300
Engine shaft speed, compressor unloaded
r/min
1700
1700
1700
1700
1700
1700
1700
Free air delivery
1)
standard
l/s
151
161
185
158
173
166
185
cfm
320
341
392
335
367
352
392
with
aftercooler
l/s
147
157
181
154
169
-
-
cfm
311
333
384
326
358
-
-
DD6.book Page 67 Monday, November 10, 2014 11:25 AM