5
Operating instructions
5.1
Initial start-up
Safety
The operator must apply all relevant
Safety precautions
.
Initial start-up procedure
1. Remove the red painted transport brackets (2).
2. Check the settings of the overload relays. See section
Electric cable size and fuses
.
3. Connect the compressor electrically. See section
Electrical connections
.
4. Close the condensate drain valve. See chapter
Condensate management
in section
Flow
diagram
.
5. Switch on the voltage. Start and stop the compressor. On 3-phase compressors, check for
correct direction of rotation (direction arrows are provided on the motors). If the rotation
direction is wrong, switch off the voltage and reverse two incoming electric lines.
5.2
Starting
Procedure
1. Open the air outlet valve. See section
Introduction
for its location.