- 41 -
5.4.2.2 Automatic start
Other actions and signals have no effect in this status.
5.4.3
Standby status
Other actions and signals have no effect in this status.
5.4.4
Permissive start status
In this status the CCM checks if the parameters are
out of range and checks all sensor inputs for sensor
faults.
This status does not require any action from the
operator, and is therefore not visible on the screen.
Yet, some buttons and signals do have a function.
Other actions and signals have no effect in this status.
If all parameters are within the defined limits,
cranking will begin, the CCM will go to the Cranking
status.
S Warnings
R Are shown on the screen
A Emergency stop button
R To emergency stop status
(see section 5.4.13)
A
↓
-button, press once
R Set pressure - 0.1 bar
A
↑
-button, press once
R Set pr 0.1 bar
A
↓
-button, press
continuously
R Set pressure - 0.1 bar/
second
A
↑
-button, press
continuously
R Set pr 0.1 bar/
second
A Power OFF switch
R End of operation
A System info button
R To system info status
(see section 5.4.14)
A OK button or Remote
start input (if Remote
control mode)
R To standby status (see
section 5.4.3)
S Warnings
R Are shown on the screen
A Emergency stop button
R To emergency stop status
(see section 5.4.13)
A
↓
-button, press once
R Set pressure - 0.1 bar
A
↑
-button, press once
R Set pr 0.1 bar
A
↓
-button, press
continuously
R Set pressure - 0.1 bar/
second
A
↑
-button, press
continuously
R Set pr 0.1 bar/
second
A Stop command
R Automatic start
deactivated. To Ready
for Start status, automatic
start (see section 5.4.2)
A Autostart pressure
reached
R To permissive start status
(see section 5.4.4)
A Power OFF switch
R Automatic start
deactivated. End of
operation
S Warnings
R Are shown on the screen
A Shutdowns
R To start failure status (see
section 5.4.11)
A Emergency stop button
R To emergency stop status
(see section 5.4.13)
A
↓
-button, press once
R Set pressure - 0.1 bar
A
↑
-button, press once
R Set pr 0.1 bar
A
↓
-button, press
continuously
R Set pressure - 0.1 bar/
second
A
↑
-button, press
continuously
R Set pr 0.1 bar/
second
A Stop command
R To ready for start status
(see section 5.4.2)
A Power OFF switch
R Automatic start
deactivated. End of
operation