- 34 -
5.3
Setting the compressor
control module
5.3.1
Control
5.3.1.1 Arrow buttons
The arrow buttons are generally used to increase or
decrease the setpressure.
In the Process Info status however, they are used to
scroll the text up and down the screen, and in the
Options status they are used to change the user
parameters.
5.3.1.2 Control modes
The CCM can be controlled via three different control
modes:
Local control mode
The CCM is controlled by means of the UI. The
Control Mode parameter is Local when the Remote
parameter is disable or disable lock.
The Local control mode is the default mode.
Remote control mode
The CCM is controlled by means of the remote
inputs; the remote control connector is located at the
back of the UI.
The Control Mode parameter is Remote when the
Remote parameter is enable or enable lock.
When this control mode is active, monitoring the
operation on the UI stays possible. Further, the UI can
only be used for looking at the System information
and the Process information, and for changing
parameters in the Options status.
PC control mode
The CCM is controlled by means of a PC. This
control mode can only be selected with the Connect
button on the PC. When the button is clicked, the
Control Mode parameter becomes remote PC,
regardless of the state of the Remote parameter.
Changing the Remote parameter will not effect the
Control Mode parameter until the Disconnect button
is clicked.
When the PC mode is active, monitoring the
operation on the UI stays possible. Further, the UI can
only be used for looking at the System information
and the Process information.
5.3.1.3 Control commands
Start command
Local:
Pressing the Start button on the UI.
Remote: Activating the Remote Start input.
PC:
Clicking the Start button on the PC.
Stop command
Local:
Pressing the Stop button on the UI.
Remote: Activating the Remote Stop input.
PC:
Clickig the Stop button on the PC.
Load command
Local:
Pressing the Load button on the UI.
Remote: Activating the Remote Load input (when
not loaded).
PC: Cliking
the
Load
button with the mouse.
Noload command
Local:
Pressing the Noload button on the UI.
Remote: Activating the Remote Load input (when
loaded).
PC:
Clicking the Noload button with the
mouse.
1
Remote
2
Internal lights
3
Heaters
4
Harness connector
0
1
1
0
PC
DDR
1
2
3
4