Set Up and Maintenance
148
9836 3521 01
Specify in
Dig output for Gear Shift
the digital output that is connected to the spindles gearshift unit. This
can be controlled using the GS - Run Gear Shift step. Enter as
<TC no.>.<channel>
, e.g. 1.4. Leave
blank if you do not have any output for this.
The
Angle correction factor
is used to calibrate the angle sensors, this is normally not necessary and
the value should be left as 1.0).
4.6.3.1 Application External Equipment
The
Enable External Equipment
checkbox should be checked when an external gearbox or similar
equipment is connected to the spindle. The following frame appears when external equipment is enabled:
Use the checkbox
Equipment Inverses Direction
if the connected equipment inverses the spindle
direction. A new
Max Torque, Max Speed
must be entered together with the
External Gear Ratio.
The
Torque Loss Factor
is used to compensate from the torque measurement loss induced by the
external equipment.
It is also recommended to supply a new
total
Wind Up Angle
that is valid for the
complete construction
(spindle inclusive the external equipment). For instructions how to calculate this value see chapter Wind
Up Coefficient in Calibration procedures in PowerMACS.
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...