Set Up and Maintenance
9836 3521 01
147
The
T/C Correction Factor
is used to calibrate the current measured as torque values.
4.6.3
Application page
The Application page contains application specific parameters, they are stored only in the setup and not
on the spindle.
Use the
Direction
field to select the basic direction for the spindle, normally
Forward
(clockwise). If the
spindle should use the inverse direction select
Backward
(counter clockwise). You can also control the
direction from the station PLC by selecting one of the items
PLC
P1
to
PLC P5
which corresponds to the
PLCs Station variables output GENOUT_1 to GENOUT_5 respectively. If the selected PLC output is set to
1 then the spindle will run forward (clockwise), otherwise backwards (counter clockwise).
Zero Speed
specifies how fast the spindle can rotate, in revolutions per minute, and still be considered
having zero speed.
If you run a JOG - Run until digital input goes high / low step, the spindle runs until a specified input goes
high or low. Specify in
Dig input for JOG steps
which digital input to supervise. Enter as
<TC no.>.<channel>,
e.g. 1.4. Leave blank if you do not have any input for this. See also the description
of I/O Device in chapter: Peripheral Devices.
Summary of Contents for PowerMACS 4000
Page 2: ......
Page 46: ...System Architecture 46 9836 3521 01...
Page 267: ...Tightening 9836 3521 01 267...
Page 400: ...Tightening 400 9836 3521 01...
Page 486: ...Peripheral Devices 486 9836 3521 01...
Page 622: ...Peripheral Devices 622 9836 3521 01...
Page 664: ...References 664 9836 3521 01...
Page 668: ...9836 3521 01 2010 11 Edition 10 3 0 www atlascopco com...