- 30 -
4.2.6
Switching on/off the floodlights
4.2.6.1
Switching on the floodlights
manually
1. Make sure the mast is up and in the desired
operating position. See section 4.2.4.
2. Switch ON the 4 circuit breakers (Q2-5) (1).
3. Push the AUTO button on the Lc1003™ module
(2) to ignite the lamps.
In sequence, every 20 seconds one lamp will
ignite automatically.
4. Wait for the lights to heat up. - this will take about
10 minutes.
4.2.6.2
Switching off the floodlights
manually
To switch the lights off manually, follow the
procedure described below and proceed to lower the
mast.
5. Push the START button on the Lc1003™ module
(1) to shut down the lamps.
6. Place the 4 automatic switches (Q2-5) (2) in their
OFF position.
7. Wait for the lamps to cool down - this will take
about 10 minutes.
When the light tower is connected to
the mains (“External power input
(230 VAC), with battery charger”
option, S10 in position 2) all lights
will ignite at the same time, as soon
as circuit breakers Q2-Q5 are
switched ON.
Q2
Q3
Q4
Q5
Q1
40A/30mA
Q6
X1
X2
0
1
P8
GE
ON
Q1
Q2 Q3 Q4 Q5 Q6
1
2
Q2
Q3
Q4
Q5
Q1
40A/30mA
Q6
X1
X2
0
1
P8
GE
ON
Q1
Q2 Q3 Q4 Q5 Q6
2
1
Once the floodlights are switched
OFF (Q2-5 switches in the OFF
position), do not to switch them ON
again until the cooling-off time is
over. The lamps will only ignite,
after complete cool down!
00_00_HiLight H4_EN.book Page 30 Monday, April 18, 2016 2:10 PM
Summary of Contents for HiLight H4 Kd ESF
Page 2: ...00_00_HiLight H4_EN book Page 2 Monday April 18 2016 2 10 PM ...
Page 81: ... 81 Circuit diagrams 00_00_HiLight H4_EN book Page 81 Monday April 18 2016 2 10 PM ...
Page 85: ... 85 00_00_HiLight H4_EN book Page 85 Monday April 18 2016 2 10 PM ...
Page 90: ... 90 00_00_HiLight H4_EN book Page 90 Monday April 18 2016 2 10 PM ...
Page 93: ...00_00_HiLight H4_EN book Page 93 Monday April 18 2016 2 10 PM ...
Page 94: ......