• The first option “Compressor Motor” will be followed by an arrow pointing to the right.
• Press the arrow down key (1) to scroll until “Dryer Motor” is followed by a horizontal arrow.
• Activate the menu by pressing tabulator key (2).
Modifying the dryer operation mode
It is possible to program three operation modes:
• Economy: the set-point of the pressure dew-point is ambient temperature minus 20 ˚C (77 ˚F) (minimum
set-point is 3 ˚C (37.4 ˚F))
• Lowest dew-point: the set-point of the pressure dew-point is ambient temperature minus 25 ˚C (68 ˚F)
(minimum set-point is 2.5 ˚C (36.5 ˚F))
• Maximum saving: the set-point of the pressure dew-point is ambient temperature minus 15 ˚C (59 ˚F)
(minimum set-point is 3 ˚C (37.4 ˚F))
Procedure
• Activate the “Dryer Motor” menu as described above.
• Press the arrow down key (1) to scroll until “Dryer Operation Mode” is followed by a horizontal arrow.
• Activate the menu by pressing tabulator key (2).
• The screen shows the actual operation mode. To modify this mode, press the Modify (F2) key; the operation
mode will flash.
• Use the scroll keys (1) to change the operation mode.
• Press the ”Program” (F1) key to program the new value or the “Cancel” (F3) key to cancel the modification
operation (the original value will be retained).
3.17 Modifying parameters
Function
Control panel
To modify a number of parameters. Consult the menu flow in section
.
Instruction book
2920 1728 05
59
Summary of Contents for GA 110 VSD
Page 1: ...GA 110 VSD GA 132 VSD GA 160 VSD Instruction book ...
Page 2: ......
Page 17: ...Rear view of air cooled GA Instruction book 2920 1728 05 15 ...
Page 23: ...Air cooled compressors Instruction book 2920 1728 05 21 ...
Page 30: ...Instruction book 28 2920 1728 05 ...
Page 31: ...Instruction book 2920 1728 05 29 ...
Page 32: ...Instruction book 30 2920 1728 05 ...
Page 33: ...Instruction book 2920 1728 05 31 ...
Page 34: ...Instruction book 32 2920 1728 05 ...
Page 35: ...Instruction book 2920 1728 05 33 ...
Page 36: ...Instruction book 34 2920 1728 05 ...
Page 79: ...Dimension drawing of air cooled Full Feature VSD compressors Instruction book 2920 1728 05 77 ...
Page 100: ...Instruction book 98 2920 1728 05 ...
Page 101: ...Instruction book 2920 1728 05 99 ...
Page 103: ...Figure A Instruction book 2920 1728 05 101 ...
Page 104: ...Figure B Instruction book 102 2920 1728 05 ...
Page 107: ...Text on figure Instruction book 2920 1728 05 105 ...
Page 164: ......
Page 165: ......