Air inlet temperature
˚F
68
Relative humidity
%
0
Working pressure
Limits
Maximum working pressure
Minimum working pressure
bar(e)
5.5
Minimum working pressure
psig
80
Maximum air inlet temperature
˚C
40
Maximum air inlet temperature
˚F
104
Minimum ambient temperature
˚C
0
Minimum ambient temperature
˚F
32
9.4
Compressor data
Note
All data specified below are valid at reference conditions; see section
Reference conditions
and limitations
.
Common compressor data
Unit
Number of compression stages
1
Temperature of the air leaving the
outlet valve (approx.), Workplace
˚C
37
Temperature of the air leaving the
outlet valve (approx.), Workplace
˚F
99
Specific data for GA 5 VSD
Unit
GA 5 VSD
GA 5 VSD
GA 5 VSD
GA 5 VSD
Normal effective working pressure
bar(e)
5.5
7
9.5
12.5
Normal effective working pressure
psig
80
102
138
181
Maximum effective working pressure,
Workplace
bar(e)
7.5
7.5
10
13
Maximum effective working pressure,
Workplace
psig
109
109
145
189
Maximum motor shaft speed
rpm
3700
3700
3200
2700
Minimum motor shaft speed
rpm
2200
2200
2200
2200
Nominal motor power
kW
5.5
5.5
5.5
5.5
Instruction book
92
2920 7104 10