Installation
EN
ETP ST101-700-F-HAD
6
© Atlas Copco Industrial Technique AB - 9839 2105 01
Installation
Installation Requirements
Connecting the tool
The tool should, via its correct Power Focus drive unit, be connected to the mains, 230V/50Hz alterna-
tively 115V/ 60Hz, single phase. See instructions for your Power Focus drive unit.
Grounding
If the tool is mounted in a handheld or hand guided fixture, the fixture should be connected to the drive us-
ing a separate 2.5mm
2
grounding cable.
Installation Instructions
Fitting of the tool cable
■
Make sure that the tool cable is of correct type.
■
Align the cable connector using the two asymmetrically positioned heads on the connector to fit in the
slots in the tool handle.
■
Tighten the lock nut.
■
Make sure that the connection is correct by pulling, pushing and turning the cable connector (there
should be no movement).
The tool has a built in electronic memory chip that will transmit the torque transducer calibration value
and angle pulses to the POWER FOCUS/drive unit. Any changes made of these values in the