Element outlet
C 116
Shdw Max 110
Menu **
**
F1 F2 F3
Fig. 6.4 Example of a shut-down warning screen
The screen shows that the temperature at the outlet of the compressor element (116 °C) is too high.
5. If necessary, stop the compressor by means of button
0
and wait until the compressor has
stopped.
6. Switch off the voltage, inspect the compressor and remedy.
7. The warning message will disappear automatically as soon as the warning condition disappears.
6.4 A service warning message exists
1. LED (7) is alight and the main screen will change into a screen similar to that shown in Fig. 6.5.
Compressor Out
bar
7.0
*Serv Requir *
Menu **
** Unld
F1 F2 F3
Fig. 6.5 Example of a warning screen
2. The indicators (**) are blinking and the service warning message appears.
3. Press the key Menu (F1) and the tabulator key (2) to select the Status data menu: the option
Service is blinking.
4. Scroll to this option and select it by pressing the tabulator key (2), two options may blink:
<<Inputs>>: if the programmed service level of a component is exceeded (e.g. the maximum
pressure drop of the oil separator).
<<Plans>>: if a service plan interval is exceeded.
5. Stop the compressor and switch off the voltage.
6. In case the service message was referring to <<Inputs>> (oil separator): replace the separator,
switch on the voltage, scroll in the Status data menu to <<Inputs>> and press the Rset key to
reset the service message.
7. In case the service message was referring to <<Plans>>: carry out the service actions related to
the indicated plans. Reset the timers of the related plans as described in section 16.