User manual
2920 1456 03
11
6 Status data menu
The status data submenu gives information regarding the status of the compressor protection
functions (shut-down, shut-down warning, service warning and warning) and allows resetting of a shut-
down, motor overload and service condition.
Procedure
Starting from the Main screen (see section 4.2):
-
Press the key Menu (F1): the option Status data will be followed by a horizontal arrow.
-
Press the tabulator key (2).
6.1 No message exists
In this case, LED (7) is out and the message on the display indicates that all conditions are normal
(Fig. 6.1):
All conditions
are OK
Menu
F1 F2 F3
Fig. 6.1 Example of a status data screen
6.2 A shut-down message exists
In case the compressor is shut down, LED (7) will blink.
In case of a shut-down due to too high a temperature at the compressor element outlet, a screen
similar to the one below will appear:
Element Outlet
C 122
Shd Max 120
Menu **
** Rset
F1 F2 F3
Fig. 6.2 Example of a status data screen