Use Atlas Copco Rock Drill AIR-OIL which is
specially developed for pneumatic rock drills. Rock
Drill AIR-OIL is readily biodegradable according to
OECD 301 and has high film strength that can
withstand heavy loads. If Rock Drill AIR-OIL is not
available use a mineral-based air tool oil with the
properties recommended in the table below.
Viscosity grade
(ISO 3448)
Temperature range
°C (F)
ISO VG 32-68
-30 to 0 (-22 to +32)
ISO VG 68-100
-10 to +20 (+14 to +68)
ISO VG 100-150
+10 to +50 (+50 to +122)
DKR 36, DKR 36R
Daily before using and after each four hours of
service, remove the plug (A) and saturate the felt
and fill the cavity with recommended oil.
Insertion tool
CAUTION Hot insertion tool
The tip of the insertion tool can become hot and
sharp when used. Touching it can lead to burns and
cuts.
►
Never touch a hot or sharp insertion tool.
►
Wait until the insertion tool has cooled down before
carrying out maintenance work.
Selecting the right insertion tool
Selecting the right insertion tool is a precondition for
proper machine function. It is important to select
insertion tools of high quality to avoid unnecessary
machine damage.
The machine can be destroyed if you use an incorrect
insertion tool.
Recommended insertion tools are listed in the
machine's spare parts list.
WARNING Vibration hazard
Using inserted tools that do not fulfil the criterias
mentioned below, will result in a longer time to
complete a task, and may result in higher levels of
vibration exposure. A worn tool will also cause
increased working time.
►
Make sure that the inserted tool is well-maintained,
not worn out and of the proper size.
►
Always use a sharp tool in order to work efficiently.
NOTICE
Never cool a hot insertion tool in water, it
can result in brittleness and early failure.
WARNING Ejected insertion tool
If the tool retainer on the machine is not in a locked
position, the inserted tool can be ejected with force,
which can cause personal injury.
►
Before changing the insertion tool, stop the
machine, switch off the compressed air supply
and bleed the machine by activating the start and
stop device.
Before fitting the insertion tool
Check that the tool shank is of the correct size and
length for the chuck used. The shank must be clean
and the tool must be in good condition. Shanks which
are chipped, rounded, out of square or too hard on
the striking end will operate inefficiently and cause
premature piston failure.
Inspect the drill steel:
A dull drill steel will slow down the drilling speed and
overstrain the drill mechanism. When changing drill
steel make sure that the new one is the correct size
to follow your previous bore.
Before drilling, check that the flushing hole in the drill
steel is not blocked.
15
© 2010 Atlas Copco Construction Tools AB | No. 9800 0938 90 | 2010-04-01
Original instructions
Safety and operating instructions
DKR 36, 36R
Summary of Contents for DKR 36
Page 2: ......
Page 6: ......
Page 23: ......
Page 26: ......
Page 48: ......
Page 70: ......
Page 92: ......
Page 114: ......
Page 133: ......
Page 136: ......
Page 155: ......
Page 158: ......
Page 161: ...161 2010 Atlas Copco Construction Tools AB No 9800 0938 90 2010 04 01 DKR 36 36R...
Page 162: ...2010 Atlas Copco Construction Tools AB No 9800 0938 90 2010 04 01 162 DKR 36 36R...
Page 163: ...163 2010 Atlas Copco Construction Tools AB No 9800 0938 90 2010 04 01 DKR 36 36R...
Page 164: ...2010 Atlas Copco Construction Tools AB No 9800 0938 90 2010 04 01 164 DKR 36 36R...
Page 165: ...165 2010 Atlas Copco Construction Tools AB No 9800 0938 90 2010 04 01 DKR 36 36R...
Page 166: ...tinnitus 2010 Atlas Copco Construction Tools AB No 9800 0938 90 2010 04 01 166 DKR 36 36R...
Page 171: ...1 171 2010 Atlas Copco Construction Tools AB No 9800 0938 90 2010 04 01 DKR 36 36R...
Page 180: ......
Page 200: ......
Page 220: ......
Page 240: ......
Page 258: ......
Page 259: ......