Unscrew the filler plug by two turns, which opens
the venting duct and releases any remaining
compressed air in the lubricator.

Fill the lubricator with oil.

Re-fit and tighten the filler plug. The lubricator is
now ready for use.

Maintenance

Regular maintenance is a basic requirement for the
continued safe and efficient use of the lubricator.
Follow the maintenance instructions carefully.

Before starting maintenance on the lubricator,
clean it in order to avoid exposure to hazardous
substances.

Use only authorised parts. Any damage or
malfunction caused by the use of unauthorised
parts is not covered by warranty or product liability.

When cleaning mechanical parts with solvent,
comply with appropriate health and safety
regulations and ensure there is satisfactory
ventilation.

For major service to the lubricator, contact your
nearest authorised workshop.

Every day

Before undertaking any maintenance on the
lubricator, always switch off the air supply and then
disconnect the air hose from the lubricator.

Clean and inspect the lubricator and its functions
each day before work commences.

Conduct a general inspection for leaks and
damage.

Check that the claw couplings are tightened and
free from damage.

Change damaged parts immediately.

Replace worn components in good time.

Make sure that all the attached and related
equipment, such as hoses are properly
maintained.

Periodic maintenance

Once a year the lubricator must be dismantled and
all parts be cleaned and checked. This work must
be performed by authorised staff, trained for this task.

Assembly instruction

When reassembling the claw couplings on the
lubricator, apply LOCTITE® 577™ (LOCTITE is a
registered trademark of Henkel Corporation. 577 is
a trademark of Henkel Corporation).

Troubleshooting

If the lubricator is not working properly, check the
following points.

G

F

B

C

D

A

E

H

Check the oil level.

Check the valve cone (A), by first removing the
stop screw (B) and then inserting a pin into the
hole. Switch the air system on and off and feel if
the valve cone (A) is opening and closing correctly.
If the valve cone (A) is not working correctly,
disconnect the lubricator from the compressed air
line and bleed the oil chamber by loosening the
filler plug (F).

Remove the spring pin (C), oil dosage screw (D)
and valve cone (A). Clean the components and if
necessary, change the O-rings. When
reassembling, make sure that the spring pin (C)
is fitted.

Make sure that the check valve (E) is sealing
effectively, if not, clean or replace the check valve
(E).

Check for leakage around the filler plug (F).

© 2015 Construction Tools PC AB | No. 9800 1172 01a | 2015-04-10

Original instructions

10

CLG 10, 10 US, 30, 30 US

Safety and operating instructions

Summary of Contents for CLG 10

Page 1: ...Safety and operating instructions Lubricators 2015 Construction Tools PC AB No 9800 1172 01a 2015 04 10 Original instructions CLG 10 10 US 30 30 US...

Page 2: ......

Page 3: ...ns 7 Storage precautions 7 Overview 8 Design and function 8 Main parts 8 Labels 8 Safety label 9 Installation 9 Hoses and connections 9 Lubrication 9 Oil adjustment 9 Operation 9 Operating 9 Filling t...

Page 4: ......

Page 5: ...f the world we can offer product support and expertise to ensure that our customers can work at maximum efficiency at all times For more information please visit www atlascopco com Construction Tools...

Page 6: ...Poor reactions and incorrect assessments can lead to severe accidents or death Never use the machine when you are tired or under the influence of drugs alcohol or medication No person who is under th...

Page 7: ...sulated If the machine comes into contact with electricity serious injuries or death may result Never operate the machine near any electric wire or other source of electricity Make sure that there are...

Page 8: ...t which it is met by the oil duct venturi tube there is an increase in air velocity and a decrease in the air pressure The small pressure differential which now exists between the oil chamber and the...

Page 9: ...ice life To guarantee good lubrication the length of the air hose between the lubricator and the pneumatic machine must not exceed 3 meters Viscosity range Viscosity Temperature C F ISO VG 46 68 200 3...

Page 10: ...ately Replace worn components in good time Make sure that all the attached and related equipment such as hoses are properly maintained Periodic maintenance Once a year the lubricator must be dismantle...

Page 11: ...hrough the mouth of the air pipe Always store the lubricator in a dry place Disposal A used machine must be treated and disposed of in such a way that the greatest possible portion of the material can...

Page 12: ...4 1 3 44 3 6 6 CLG 10 6 15 13 32 0 28 4 06 0 1 2 4 1 3 44 3 6 6 CLG 10 US 25 130 53 275 0 28 4 06 0 1 2 4 1 3 44 3 6 6 CLG 30 25 130 53 275 0 28 4 06 0 1 2 4 1 3 44 3 6 6 CLG 30 US 25 130 53 275 0 28...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...copying of the contents or any part thereof is prohibited This applies in particular to trademarks model denominations part numbers and drawings www atlascopco com 2015 Construction Tools PC AB No 98...

Reviews: