Installation requirements

Air quality

For optimum performance and maximum product life we recommend the use of compressed air with
a maximum dew point of +10°C (50°F). We also recommend to install an Atlas Copco refrigeration
type air dryer.

Use a separate air filter which removes solid particles larger than 30 microns and more than 90% of
liquid water. Install the filter as close as possible to the product and prior to any other air preparation
units to avoid pressure drop.

For impulse/impact tools make sure to use lubricators adjusted for these tools. Regular lubricators
will add too much oil and therefore decrease the tool performance due to too much oil in the motor.

Make sure that the hose and couplings are clean and free from dust before connecting to the tool.

Both lubricated and lubrication free products will benefit from a small quantity of oil supplied from a
lubricator.

Air lubrication guide

Brand

Air lubrication

Atlas Copco

Optimizer (1 liter) 9090 0000 04

Q8

Chopin 46

Shell

Shell Air Tool Oil S2 A 320

Compressed air connection

WARNING Compressed air can cause serious injury

Always shut off the air supply, drain hose of air pressure and disconnect the tool from air supply;
when not in use, before making any adjustments to the product - for example changing acces-
sories, or when making repairs.

WARNING Whipping hoses can cause serious injury

Always make sure that there are no damaged or loose hoses or fittings.

WARNING Compressed Air

High air pressure can cause severe damage and bodily injury.

Do not exceed maximum air pressure.

Make sure that there are no damaged or loose hoses or fittings.

For correct air pressure and hose size, see section 

Technical data

.

Make sure that the hose and couplings are clean and free from dust before connecting to the tool.

Summary of Contents for 8431035021

Page 1: ...alid from Serial No Product Instructions W2621 5 68 Nm 8431035021 WARNING Read all safety warnings and instructions Failure to follow the safety warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference ...

Page 2: ...DS 4 Warning 4 Country of origin 4 Dimensional drawings 4 Service overview 4 Service recommendations 4 Installation 5 Installation requirements 5 Air quality 5 Air lubrication guide 5 Compressed air connection 5 Operation 6 Ergonomic guidelines 6 Service 7 Maintenance instructions 7 Service recommendations 7 Lubrication instructions 7 Lubrication guide 7 Recycling 8 Recycling instruction 8 ...

Page 3: ...sonal injury Warranty Product warranty will expire 12 months after the product is first taken into use but will in any case ex pire at the latest 13 months after delivery Normal wear and tear on parts is not included within the warranty Normal wear and tear is that which requires a part change or other adjustment overhaul during standard tools maintenance typical for that period expressed in time ...

Page 4: ... fever with flu like symptoms especially when smoking contaminated tobacco Health and Safety recommendations for PTFE must be followed when handling vanes and other com ponents Do not smoke when servicing this product PTFE particles must not come in contact with open fire glow or heat Motor components must be washed with cleaning fluid and not blown clear with an air line Wash your hands before st...

Page 5: ...ore connecting to the tool Both lubricated and lubrication free products will benefit from a small quantity of oil supplied from a lubricator Air lubrication guide Brand Air lubrication Atlas Copco Optimizer 1 liter 9090 0000 04 Q8 Chopin 46 Shell Shell Air Tool Oil S2 A 320 Compressed air connection WARNING Compressed air can cause serious injury Always shut off the air supply drain hose of air p...

Page 6: ...st for convenient field of vision by minimizing movement of the eyes and head during the work task Use the appropriate lighting for the work task Select the appropriate tool for the work task Use ear protection equipment in noisy environments Use high quality inserted tools or consumables to minimize exposure to excessive levels of vibration Minimize exposure to reaction forces When cutting A cut ...

Page 7: ...inspect it If no detailed information about preventive maintenance is included follow these general guidelines Clean appropriate parts accurately Replace any defective or worn parts Lubrication instructions Lubrication guide Brand General purpose Bearings and Gears BP Energrease LS EP2 Castrol OBEEn UF 1 Esso Beacon EP2 Q8 Rembrandt EP2 Mobil Mobilegrease XHP 222 NLG 2 Klüber Lub Klübersynth UH 1 ...

Page 8: ...01 Recycling Recycling instruction When a product has served its purpose it has to be recycled properly Dismantle the product and recycle the components in accordance with local legislation Batteries shall be taken care of by your national battery recovery organization ...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...erved Any unauthorized use or copying of the contents or part thereof is prohibited This applies in particular to trademarks model denominations part numbers and drawings Use only authorized parts Any damage or malfunction caused by the use of unauthorized parts is not covered by Warranty or Product Liability Out of respect to wildlife and nature our technical literature is printed on environmenta...

Reviews: