31
1.7 Operation Test
Connect the UPS to the wall receptacle.
With the UPS plugged in, press and hold the On/Off button more than 1
seconds until hearing one short beep sound to switch the UPS on, then UPS
is in the displaying condition. If use UPS for first time, please let UPS
operate for 10 hours emptily to charge battery so that battery can't be in
low capacity.
Connect your computer equipment with sockets of the UPS and pull off the input
power cable of the UPS from the wall receptacle to check if the LED Battery is
Orange. Meanwhile, please check if alarm buzzer is beeping (3 beep every 6
seconds). Check if the UPS is initiated properly to support continuous operation.
Try the field working condition by running some application programs on your
computer and repeating step.
When UPS is operating, press On/Off button and hold 2 seconds until
switch off (Switch off UPS, must turn off the equipment which connect to
UPS, Then press On/Off button).
Plug the UPS into the wall outlet to charge the UPS for over 10
hours before using the UPS.
Before connect with equipment power supply line, please
count the total equipment watt. The number must lower
than UPS output watt. If it higher than UPS output watt,
please reduce some equipment, or UPS will lock under
backup power condition (display FAULT and continuos
alarm).