Keep the outdoor unit away from heat sources and
inflammable products.
•
Make sure the appliance not disturb the surrounding
area or users (noise level, draught generated, low
temperature of the air being blown out, with the risk of
freezing plants in its path).
•
The surface on which the appliance is installed must:
-
be permeable (soil, gravel, etc),
-
support its weight easily,
-
provide a solid fixing and
-
not transmit any vibration to the dwelling.
(Anti-vibratory blocks are available as an option).
•
The wall bracket can not be used in conditions likely to
transmit vibrations, ground position is preferred.
2 .4 .2 Outdoor unit positioning
The outdoor unit must be raised at least 50 mm above
ground level. In areas prone to snow, this height should
be increased but should not exceed 1.5 m (
-
Fasten the outdoor unit by means of screws and
rubber tightening or toothed lock washers to avoid
their coming loose.
"
Warning
In the area with heavy snowfall, if the intake and outlet
of outdoor unit is blocked with snow, it might become
difficult to get warm and it is likely to cause of the
breakdown.
Please construct a canopy and a pedestral or place the
unit on high stand (local configured).
-
Set the unit on a strong stand, such as one made of
concrete blocks to minimize shock and vibration.
-
Do not set the unit directly on the ground because it will
cause trouble.
2 .4 .3 Condensate drain hose
).
"
The outdoor unit can generate a large volume of
water (called condensate).
If the use of a discharge pipe is imperative:
-
Use the elbow provided (
C
) to connect a 16mm-
diameter hose for draining away the condensate.
-
Use the stopper or stoppers provided (
B
) to block the
opening of the condensate drain pan.
Allow for the condensate to flow away under the force of
gravity (waste water, rain water, gravel bed).
"
If the installation is made in an area where
the temperature can be lower than 0°C for
a long period, provide the drain pipe with a
trace resistance to avoid it icing up . The trace
resistance must heat not only the pipe but also
the bottom of the the outdoor unit .
figure 15 - Fitting the outdoor unit,
evacuation of the condensates
B
B
B
C
C
C
B
* Dans les régions fréquemment enneigées,
(H) doit être supérieur à la couche moyenne de neige.
(Ø 12 mm)
(Ø 10 mm)
Suivant modèle
Suivant modèle
4 trous
4 trous
H > 50 mm
*
H* ≥ 50mm
B
B
B
B
C
C
4
holes
(ø 12 mm)
Depending on model
* In regions with frequent snowfall, (H) must be greater
than the average layer of snow.
Depending on model
Depending on model
4 holes
4 holes
Installation and commissioning instructions "1485 - EN"
Heat pump alféa hybrid duo gas
- 18 -
Summary of Contents for WOYG112LHT
Page 51: ... Installation and commissioning instructions 1485 EN 51 Heat pump alféa hybrid duo gas ...
Page 69: ... Installation and commissioning instructions 1485 EN 69 Heat pump alféa hybrid duo gas ...
Page 90: ...Installation and commissioning instructions 1485 EN Heat pump alféa hybrid duo gas 90 ...
Page 91: ...Installation and commissioning instructions 1485 EN 91 Heat pump alféa hybrid duo gas ...