TECHNICAL DATA

 

STORAGE

Model

PLM9KE-410

PLM12KE-410

PLM15KE-410

PLM9KEH-410

PLM12KEH-410 PLM15KEH-410

Cooling capacity *

BTU/h

9000

12000

15000

kW

2.6

3.5

4.4

Power consumption

-Cooling

-Heating (EH only)

0.8

1.0 

 

1.5

kW

1.75

1.68

R410A / 500

R410A / 630

-Heating element (EH only)

Mains

V / Hz / PH

220 - 240 / 50 / 1

Compressor model

rotary

Fan speeds

3 (2+1 turbo)

Thermostatic range

°C

18 - 32

Refrigerant charge

type / g

R410A / 420

Dimensions (w x h x d)

mm

500 x 840 x 415

Net weight

kg

33.1

34.3

39.3

*  Enthalpy method at 27˚C, 60% RH.

PLM9KEHx-410 and PLM9KEx-410 series can be connected only to a supply with system impedance no more 
than 0.383 Ohm.
PLM12KEHx-410 and PLM12KEx-410 series can be connected only to a supply with system impedance no 
more than 0.247 Ohm.
PLM15KEHx-410 and PLM15KEx-410 series can be connected only to a supply with system impedance no 
more than 0.110 Ohm

If necessary, please consult your supply authority for system impedance information.

 

Subject to modifi cations without prior notice.  For greater precision, please refer to the rating label placed on 
the product.

Empty the internal water container.
Clean the screen filter.
Remove 3M™ High Air Flow filter and active carbon filter.

• Remove the 3M™ High Air Flow  filter and active carbon filter before end of 

season storage and install new filters at the beginning of the new seasons.

The old filters can be disposed of in the ‘Non-biological rubbish
container’.

• Replacement filter packages are available from Atlantic.

Put the unit in Fan Only mode for a few hours to ensure that the inside
becomes completely dry.
Store the cable as shown.

Protect the unit against dust and store in a dry place, not accessible to children.

Summary of Contents for PLM 12KE-410

Page 1: ...s c o l b o n o m M L P PLM ENGLISH INSTRUCTION MANUAL 9KE 410 12KE 410 15KE 410 PLUS HEATER VERSIONS ...

Page 2: ......

Page 3: ...nsed electrician Any service other than regular cleaning or filter replacement should be performed by an authorized service representative Failure to do so could result in a loss of warranty A damaged supply cord should be replaced by the manufacturer its service agent or a qualified person in order to avoid a hazard WARNING Never operate this appliance if it has a damaged cord or plug Do not lead t...

Page 4: ...ge point Slide bar connector Air outlet Control panel Carrying handle Caster wheels Air filter Telescopic slide bar Exhaust hose Water container Remote control Controls ON OFF UP DOWN MODE TIMER SLEEP FAN SPEED Display COOLING FAN HOURS MINUTES TEMPERATURE HEAT for models with heater only ...

Page 5: ...w filter white where included in the filter holder Place the filter fixer back in the holder Place the filter holder back in the air conditioner Do not operate the unit inside the bathroom shower or in any other very humid environment Connect the hose to the unit by turning it clockwise at least 5 turns Similarly connect the hose to the slide bar connector as far as possible Place the telescopic slide ...

Page 6: ...hing any button on the control panel the backlight will switch on again Heat for models with heater only EH models feature a 1680 W electric heater that can heat a room on cooler days With the mode switch select set the desired temperature and the unit will heat until this temperature is reached Fan speed is selected automatically Do not place the unit near anything that could catch fire or be scor...

Page 7: ... the timer function In order to cancel the timer programming press the button momentarily then it will return to the time display The daily mode will be cancelled as well The black segments in the circular time scale will disappear Air flow Direct the air flow by adjusting the grill on top of the air conditioner Move the grill by pushing or pulling in the middle see illustration This will avoid unev...

Page 8: ...llen bacteria animal dander and dust Selected models have the 3M High Air Flow filter as standard However if you require to add this to your model or wish to purchase a replacement call Atlantic for details NOTE The active carbon filter and the 3M High Air Flow filter are delivered in a plastic packaging Don t forget to install these filters These filters take away unhealthy particles out of the room e...

Page 9: ...move the water stopper and rubber plug from the drain and let the water run out The water container has to be emptied several times before all water will be drained ca 1 5 litres Replace the rubber plug and water stopper put the plug into the wall socket and switch the unit on The warning signal should be off NOTE When the air conditioner is in use under normal circumstances the condensed water wil...

Page 10: ...nit stands uneven Place on an even solid surface less vibrations The compressor does not work The overheat protection is probably activated Wait 3 minutes until the temperature has decreased then turn on the unit again The remote control does not function Distance too great Make sure the remote control is correctly aimed at the control panel Remote control signal not detected by the control panel ...

Page 11: ...than 0 247 Ohm PLM15KEHx 410 and PLM15KEx 410 series can be connected only to a supply with system impedance no more than 0 110 Ohm If necessary please consult your supply authority for system impedance information Subject to modifications without prior notice For greater precision please refer to the rating label placed on the product Empty the internal water container Clean the screen filter Remov...

Page 12: ...f the product is modified misused or repaired by an unauthorised person The guarantee does not cover accidental damage misuse or consumable items such as filters The guarantee after repair or replacement will not be extended beyond the original two year period All replacement parts or units will be new or reconditioned Parts or units which are replaced become the property of Atlantic Australasia A...

Reviews: