- 4 -
Technical characteristics
Dimensions
mm
H 1897 x l 591 x D 674
Empty weight
kg
90
Capacity of the tank
L
270
Hot water / cold water connection
3/4 ’ ’ M
Corrosion-proof protection
Impressed current anode
Minimum conductivity of the water
μ
S/cm 40
Rated pressure
Permissive excessive operating pressure
kPa
Mpa
560
1
Electric connection (voltage / frequency)
240 V single phase 50 Hz
Maximum total power input of the appliance
W
2635
Average power input of the heat pump
W
425
Maximum power input of the heat pump
W
755
Power output of the heat pump
(under nominal cond15°C)
W
1660
Power input of the electric backup
W
1880
Water temperature setting range of the heat pump
°C
45 to 62 (factory setting =
55°C)
Operating temperature range of the heat pump (air temperature)
°C
-5 to 35
Vacuum air flow (without duct) (230V)
Speed
1
m
3
/h 230
Speed
2
m
3
/h 390
Admissible head loss in the air circuit without impacting
performance
Pa 25
Noise level**
dB(A) 54
Acoustic pressure at 2m in the open
dB(A) 37
Coolant fluid
Nota : R134a GWP (Global Warming Potential) is 1350
-/kg
R134a / 1.35
Certified performances at an air temperature of 7°C (CDC LCIE 103-15A) and 25Pa** ducting
Coefficient of performance (COP) (230V)
3,1
QPr (over 24h) (230V)
kWh 0,77
Heating time* (230V)
8h19min
Performance measured at an air temperature of 15°C (CDC LCIE 103-15A) without ducts**
Coefficient of performance (COP) (230V)
3,8
QPr (over 24h) (230V)
kWh 0,74
Heating time* (230V)
7h30min
Other performances
Max. quantity of water mixed at 40°C (setting at 62°C)
L
455L
* Tested in a reverberation chamber in accordance with the measurement standard NF EN ISO 3741,
water heaters without accessories, average measurement when heating from a water temperature of 21 to
57°C at an ambient air temperature of 20°C.
** Performances measured when heating water from 15°C to 51°C according to the protocol in the
specifications of the NF Electricity performance brand N° LCIE 103-15A for standalone accumulator tank
thermodynamic water heaters (based on the standard EN 255-3).
This appliance complies with Directives 2004/108/EEC on electromagnetic compatibility and 2006/95/EEC
on low voltage.