Heat Pump Configuration
▼
Heat Pump
"
Minimum shutdown time
":
0 mins... 120 mins.
"
Max HP T°
":
8°C... 100°C.
"
Post-circulation
":
10 secs... 600 secs.
"
Power shedding operating
":
Automatic
,
When needed.
Released: HP = Start / DHW Backup = Stop / 1
st
HP Backup = Stop /
2
nd
HP Backup = Stop / Boiler = Start.
When needed (Locked): HP = Stop / DHW Backup = Stop /
1
st
HP Backup = Stop / 2
nd
HP Backup = Stop / Boiler = Start.
HP
Compressor configuration
Minimum shutdown time
8 mins
Post-circulation
240s
Max HP T°
75°C
Power shedding
operating
Released
1
- "
Summer/winter switchover outd.T°
" Zone 1:
8°C... 30°C.
"
Mini. cooling switchover outd. T°
":
8°C... 35°C.
"
Mini. time prior to heat./cool.switchover
":
8h... 100h.
2
- "
Circuit 2 heating
":
0°C... 20°C.
- "
Circuit 2 cooling
":
0°C... 20°C.
1
HP
Heating/cooling configuration
Summer/winter switchover
outd.T°
18°C
Mini. cooling switchover
outd. T°
---
Mini. time prior to heat./
cool.switchover
24h
Next
2
HP
Complete
Heating/cooling configuration
Mixing valve compensation
Area 2
Area 2 heating
0°C
Area 2 cooling
0°C
"
Maximum HP DHW T°
":
0°C... 80°C.
"
Switching differential
":
0°C... 20°C.
"
Heat./cool. alternating time
":
10 mins... 600 mins.
(with dynamic radiator, set to 40 mins).
HP
DHW configuration
Maximum HP DHW T°
52°C
Switching differential
7°C
Heat./cool. alternating time
90 mins
Some settings (or menus) might not be displayed. They are dependent on the installation's configuration (and installed options).
HP configuration
HP
Compressor configuration
Heating/cooling configuration
DHW configuration
- 58 -
alfea Excellia HP Duo A.I. / Installation / 1945 - EN