background image

Installation of Colorfalls

The opening in the wall where the  
Colorfalls will be placed is important to  
the function of the Colorfalls. If it is not  
level and free of debris the Colorfalls will  
not function properly. The base of  
Colorfalls body (A) as well as the bottom  
of the spillway lip (B)  must be supported  
by the opening in which it is placed. The  
top side of the opening (C) must also be  
in contact with the Colorfalls to prevent  
it from shifting. See Figure 1 for the proper  
sizing of the opening for the Colorfalls.  

No more than one inch of spillway  
should extend out from the wall.

Introduction

Thank you for choosing Atlantic’s Colorfalls. The Colorfalls are designed for use in  
Pond-free and fountain applications and install easily into most retaining walls. Colorfalls 
feature low energy LED lights, an extra-long reinforced weir, and an interior baffling system 
that produces a single, lighted water sheer.  

Prior to Operation and Installation

Caution:

•  DO NOT operate this product under any condition other than those for which it is  
    specified. Failure to observe these precautions can lead to electrical shock, product  
    failure, or other problems.
•  Follow all aspects of electrical codes when installing the Colorfalls. 
•  To reduce the risk of electrical shock, connect only to a 110 volt receptacle protected by a  
   ground fault circuit interrupter (GFCI). 
•  Colorfalls are designed for use in Pond-free and fountain applications.  Colorfalls are not  
   intended for use in water gardens or any pond with plant or aquatic life.
The Colorfalls must be accessible for service and maintenance. Installing the Colorfalls so 
that the entire body is removable is highly recommended. 

Do not glue the cap stones 

above the Colorfalls or permanently mortar the Colorfalls  in place.

The Colorfalls can support 40 lbs. per linear foot (e.g. a 24" Colorfalls can support 80 lbs.).  
If the weight on the weir exceeds that amount, you will need to provide a lintel support  
for the added weight. This support should still make contact with the weir to prevent it 
from shifting. 
See the chart below for the recommended placement of the Colorfalls above the basin or 
pool. If the placement of the Colorfalls exceeds the recommended height, water loss will 
increase significantly due to splash and wind drift.

2

Colorfalls

Maximum Falls Height Above Basin

Flow Rate

CF12

18" - 24"

1000 GPH

CF24

24" - 30"

2000 GPH

CF36

30" - 36"

3000 GPH

3⅜"

4"

4"

½"

Figure 1

Summary of Contents for 73833

Page 1: ...B 73833 CF12SW 73844 CF12W 73885 CF24B 73886 CF24SW 73887 CF24W 73888 CF36B 73889 CF36SW 73890 CF36W 73891 Product Manual Manuel du Produit Manual del Producto 1 330 274 8317 www ATLANTICWATERGARDENS com FS ...

Page 2: ...electrical shock product failure or other problems Follow all aspects of electrical codes when installing the Colorfalls To reduce the risk of electrical shock connect only to a 110 volt receptacle protected by a ground fault circuit interrupter GFCI Colorfalls are designed for use in Pond free and fountain applications Colorfalls are not intended for use in water gardens or any pond with plant or...

Page 3: ...d control of water flow Figure 2 Operation Connect the light bar to the transformer using the two pronged quick connect plug Plug the 12 volt AC transformer into a standard 120 volt outlet Connect the tubing to the properly sized pump not included and turn the pump on Warranty Colorfalls and all its components carry a one year limited warranty This limited warranty is extended solely to the origin...

Page 4: ...Clear debris from pump intake Check pump manual for cleaning Obstruction in plumbing line Clear any debris from plumbing Waterfall sheer is splitting Debris in Colorfalls spillway Refer to Maintenance Not enough water flow Double check pump flow See diminished water flow Troubleshooting Guide Always turn off power before inspecting the Colorfalls Failure to observe this precaution can result in a ...

Page 5: ...are avec des plantes et de la vie aquatique Elles doivent rester accessibles pour les interventions de service et d entretien Les installer de façon à ce que leur corps entier soit amovible est fortement recommandé Ne collez pas les pierres de couverture par dessus la Colorfalls et ne la scellez pas en place de façon permanente avec du mortier La chute peut supporter 40 lbs par pied linéaire ou 18...

Page 6: ... arrière du corps Raccordez la conduite de plomberie venant de la pompe sur la Colorfalls l utilisation de tube d au moins 1 3 8cm de diamètre est recommandée Un tube plus étroit amènera un flux inadéquat et une cascade brisée Du tuyau en PVC est recommandé parce que du tuyau annelé avec raccords d insertion réduit le flux L installation d une vanne à boisseau non incluse sur la conduite d aliment...

Page 7: ...ns Si vous n y décelez pas la solution au problème contactez votre revendeur Problème Cause possible Solution possible La rampe lumineuse ne s allume pas Pas de secteur sur la prise Confirmez la présence de secteur à la prise Pas d alimentation depuis le transformateur Confirmez la sortie de tension du transformateur Pas d alimentation à la barre lumineuse Contrôlez si le cordon est endommagé De l...

Page 8: ...destinadas a su empleo en jardines acuáticos ni en ningún estanque con vida vegetal o acuática Las Colorfalls deben ser accesibles para el servicio y el mantenimiento Se recomienda especialmente instalar las Colorfalls de manera que el cuerpo completo sea desmontable No adhiera las piedras cimeras que están sobre las Colorfalls ni asiente con mortero las Colorfalls para instalarlas de manera perma...

Page 9: ...io de una conexión roscada macho de 1 3 8cm a elección no incluida Aplique silicona a las roscas de la conexión macho Enrosque la conexión en la entrada de la Colorfalls hasta ajustarla Apriete sólo con la fuerza de la mano Si se aprieta demasiado se puede romper el dorso de la unidad Mantenimiento La Colorfalls de Atlantic es una unidad cerrada de una sola pieza Si ingresan desperdicios en el cue...

Page 10: ... de plomería de la parte posterior y aspire el agua con una aspiradora de taller o sóplela con un compresor de aire La mejor opción es quitarla totalmente de la pared y almacenarla en interiores Problema Causa posible Solución posible La barra de luces no se enciende No llega alimentación eléctrica al tomacorriente Confirme que llegue alimentación eléctrica al tomacorriente No hay alimentación elé...

Page 11: ...11 ...

Page 12: ...1 330 274 8317 www ATLANTICWATERGARDENS com ...

Reviews: