PRODUCT APPLICATION

C

onstruCtion

•  These units have been designed to be CE compliant. These units have been tested to and comply with the requirements of 

the Electromagnetic Compatibility Directive and the Machinery Directive. The Declaration of Conformity lists the European 

Norm (EN) standards to which these units were tested, to demonstrate conformity.

• 

The water purifier is designed to mount horizontally. 

• 

The water purifier’s chamber and chamber head are passivated and electropolished type 316 Stainless Steel.

•  The ballast housing is a combination of Stainless Steel Type 304 and Aluminum Alloy.

•  EASY-OFF

 End Caps enable quick and easy lamp change, without disconnecting from the water supply or draining the 

purifier. No tools are required. 

Always disconnect electrical power when changing lamp.

• 

Coated chambers are available for uses with special applications, consult Factory. Coated chambers are not recommended for 

use in drinking water applications or in applications where the treated product is consumed.

• 

The water purifier’s removable chamber head design facilitates the ease of maintenance 

(

SANITRON

®

 

 

m

oDel

 s37C 

only

)

• 

A drain port on the chamber aids in draining of the purifier.

•  The dual action wiper mechanism allows for quick and easy quartz sleeve cleaning, without interrupting service. 

(

SANITRON

®

 

 

m

oDel

 s37C 

only

)

P

rinCiPle

 

of

 o

Peration

The

 SANITRON

®

 

/ MIGHTY

«

PURE

®

 

design has been carefully conceived to provide adequate germicidal dosage throughout 

the disinfection chamber. The dosage, as it applies to ultraviolet disinfection, is a function of time and the intensity of ultraviolet 

radiation to which the water is exposed. The exposure time, in seconds, is the total time it takes the water to flow through the 

disinfection chamber exposing it to the germicidal lamp. Exposure time is related to the flow rate; the higher the flow rate, the 

lower the exposure time or the lower the flow rate, the higher the exposure time. The ultraviolet intensity is the amount of energy, 

per unit time, emitted by the germicidal lamp. The dosage is the product of ultraviolet intensity and the exposure time. The 

operation of the 

SANITRON

®

 

/ MIGHTY

«

PURE

®

 is as follows:

• 

Water enters the purifier and flows into the annular space between the quartz sleeve and the chamber wall.

•  Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp.
•  The translucent sight port, or optional ultraviolet monitor, provides visual indication of germicidal lamp operation.
• 

Water leaving the purifier is instantly ready for use, no further contact time is required.

•  The dual action wiper mechanism facilitates periodic cleaning of the quartz sleeve without disassembly or interruption of 

purifier operation. 

(

SANITRON

®

 

m

oDel

 s37C 

only

)

l

imitation

 

of

 u

se

The water purifier is intended for the use with visually clear water, not colored, cloudy or turbid. See 

“Water Quality”

 section 

below. The water purifier is 

NOT

 intended for the treatment of water that has an obvious contamination or intentional source, 

such as raw sewage; nor is the unit intended to convert wastewater to microbiologically safe drinking water.

W

ater

 Q

uality

Water quality plays a major role in the transmission of germicidal ultraviolet rays. It is recommended that the water does not 

exceed the following maximum concentration levels:

Table 1 - Maximum Concentration Levels

Turbidity

< 1 NTU

Manganese

0.05 mg/1

Total Suspended Solids

10 mg /1

pH:

6.5 - 9.5

Color:

None

Hardness

6 GPG or 102.6 PPM

Iron

0.3 mg/1

Tannins:

< 0.1 ppm (0.1 mg/l)

UV Transmission

>85% per cm*

* Contact Factory for recommendations on applications where 

 

UV transmission is < 85%

Effectively treating water with higher concentration levels than 

listed can be accomplished, but may require added measures to 

improve water quality to treatable levels. If, for any reason, it is 

believed the ultraviolet transmission is not satisfactory, contact 

the factory.

Summary of Contents for Mighty Pure MP36C

Page 1: ... THE USA Installation Operation Maintenance Read and Follow All Safety Instructions Save These Instructions Models Sanitron S37C Mighty Pure MP36C Designed for CE Compliance ULTRAVIOLET WATER PURIFIERS ULTRAVIOLET WATER PURIFIERS Extensive Product Information Available at ultraviolet com buyultraviolet com ...

Page 2: ...2 MAINTENANCE NOTES 23 USER ASSISTANCE PRODUCT REGISTRATION 24 WARRANTY 24 Patent Notice 24 These instructions generally describe the installation operation and maintenance of the CE Compliant water purifiers MIGHTY PURE Model MP36C and SANITRON Model S37C Questions that are not specifically answered by these instructions should be directed to the Factory Atlantic Ultraviolet Corporation takes all...

Page 3: ... POTENTIALLY hazardous situation which if not avoided COULD result in death or serious injury This symbol pictorial is used to identify the need to wear approved ultraviolet blocking eyewear This symbol pictorial is used to identify the need to wear approved ultraviolet blocking face shield This symbol pictorial is used to identify components which must not be disposed of in trash Danger indicates...

Page 4: ...flow rate the lower the exposure time or the lower the flow rate the higher the exposure time The ultraviolet intensity is the amount of energy per unit time emitted by the germicidal lamp The dosage is the product of ultraviolet intensity and the exposure time The operation of the SANITRON MIGHTY PURE is as follows Water enters the purifier and flows into the annular space between the quartz slee...

Page 5: ... of use This reduces the chance of the purified water being re contaminated by bacteria in the water distribution system after the water purifier 6 As with any water handling device the water purifier should be located in an area where any possible condensation or leakage from the water purifier any purifier accessory and or plumbing will not result in damage to the area surrounding the water puri...

Page 6: ...talled on both the inlet and outlet sides of the water purifier The use of bypass valves is not recommended The shut off valves allow the purifier to be isolated from the water supply which is required when removing the quartz sleeve 7 Unions should be installed on both the inlet and outlet of the water purifier this will allow easy removal of the water purifier from the plumbing if required Apply...

Page 7: ...SureFLO Flow Control Valve Limits water flow to the rated capacity of the purifier The flow control valve is located in line prior to the water purifier and should be protected from ultraviolet exposure by the use of a 90 degree elbow fitting between the flow control valve and the water purifier 5 Promate Audio Alarm Activated by the Ultraviolet Monitor or Safety Sensor alerts the user to any malf...

Page 8: ...ing Contact factory with questions Inspection 1 Regularly inspect the water purifier to ensure that the germicidal lamp is still in operation On purifiers not equipped with the Ultraviolet Monitor lamp operation can be verified by a visible glow through the translucent sight port This provides an indication of lamp operation and does not indicate the level of ultraviolet intensity or transmission ...

Page 9: ...Next carefully slide lamp back into chamber until approximately 2 inches of the lamp is exposed on the opposite end Hold lamp and remove lamp socket 6 Lamp should now be disconnected on both ends Carefully remove lamp from chamber Be sure to withdraw lamp straight out without angling until completely clear of quartz sleeve Lamp and quartz sleeve are easily damaged Exercise care when handling 7 Rei...

Page 10: ...uartz sleeve is easily accomplished using the dual action wiper mechanism 1 Lift wiper clip up and away from wiper rod 2 Grasp wiper knob and gently pull out away from the purifier until it reaches its stop 3 Push wiper back in toward the purifier until it reaches its second stop 4 Repeat steps 2 and 3 as necessary 5 Holding wiper in place return wiper clip and snap over wiper rod in front of the ...

Page 11: ...es remain within the static gland nut If so remove Teflon washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end with your finger so that it does not drop to the bottom of the chamber as it slides into the chamber 7 Once the quartz sleeve is removed clean with alcohol or a mild non abrasive ...

Page 12: ...through the gland fitting Flush water through chamber being careful to remove all quartz fragments from the interior of the chamber 5 Carefully discard all pieces of the broken quartz sleeve 6 Align the end of the replacement quartz sleeve with the gland fitting of the chamber 7 Carefully slide the quartz sleeve into the chamber guiding it through the gland fitting NOTE Use care to keep the quartz...

Page 13: ... nut from the head clamp 4 Withdraw chamber head and wiper assembly from the chamber 5 Any broken pieces of the quartz sleeve can now be removed through the open end of the purifier chamber Flush water through chamber being careful to remove all quartz fragments from the interior of the chamber 6 Carefully discard all pieces of the broken quartz sleeve 7 Inspect the large O Ring used to seal the c...

Page 14: ...nd outlet shut off valves Remove drain plug and drain the chamber Once the chamber is drained remove any old sealing tape from the threads of the drain plug rewrap with 1 2 wide Teflon thread sealing tape reinstall and tighten the drain plug 3 Disconnect power to the Ultraviolet Monitor remove from chamber by loosening the two set screws on the aluminum collar and lifting it free from probe body 4...

Page 15: ...in and remove static gland nut replace sealing O Ring See Quartz Sleeve Installation or Replacement in the Maintenance section Poor or loose connections or fittings Tighten suspect connection or fitting or shut down purifier drain and remove fitting or connection Clean threads reapply thread sealing tape and reinstall Poor purifier disinfection performance AND OR Low UV intensity As indicated on o...

Page 16: ...60Hz Length 37 3 8 50 3 8 Width 5 11 16 5 11 16 Height 9 1 2 9 1 2 Chamber Diameter 4 1 4 4 1 4 Lamp Model No 05 1343 R 05 1343 R Ultraviolet Output 15 Watts 15 Watts Lamp Watts k 41 Watts 41 Watts Rated Life of UV Lamp 10 000 Hrs 10 000 Hrs All specifications dimensional data etc are approximate and subject to change without notice M M Ultraviolet output at 254nm at 100 hours and 80 F approximate...

Page 17: ...17 Mighty Pure Model MP36C Figure 9 Exploded View MP36C ...

Page 18: ... 1 15 1113A 9 Sight Port Plug 1 30 1075 10 Chamber 1 25 1465G4 11 Drain Plug 1 27 1216 12 Screw 1 4 20 x 3 8 Long 4 50 1034 13 Lock Washer 1 4 4 50 1321 14 Flat Washer 1 4 4 50 1317 15 Ballast Housing Cover 1 25 0394A 16 Screw No 8 x 3 8 Long 8 50 1323 17 Speed Nut 6 32 2 50 1314 18 Surelite Ballast Elect 230V 10 1 10 0115 19 Ferrite EMI Suppression 2 35 1749 20 Ballast Housing 1 25 1164A 21 Screw...

Page 19: ...19 SANITRON Model S37C Figure 10 Exploded View S37C ...

Page 20: ...1 16 Wiper Knob 1 25 1222 17 Wiper Lock Spacer 1 25 1512A1 18 Wiper Clip 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 20 Drain Plug 1 27 1216 21 Screw 1 4 20 x 3 8 Long 4 50 1034 22 Lock Washer 1 4 4 50 1321 23 Flat Washer 1 4 4 50 1317 24 Ballast Housing Cover 1 25 0394A 25 Screw No 8 x 3 8 Long 8 50 1323 26 Speed Nut 6 32 2 50 1314 27 Surelite Ballast Elect 230V 10 1 10 0115 28 Ferrite EM...

Page 21: ...21 ...

Page 22: ...22 ...

Page 23: ...23 MAINTENANCE NOTES ...

Page 24: ...t will be free from defects in material and workmanship for a period of one year from the date of shipment thereof or the product s total rated life whichever first occurs Within the warranty period we shall repair or replace such products which are returned to us with shipping charges prepaid and which are determined by us to be defective This warranty will not apply to any product which has been...

Reviews: